PROGRAMMING OF THE UPPER POSITION OF
END-OF-STROKE SENSOR
To set the upper position of the end-of-stroke sensor on a
roll-up shutter equipped with lock on the upper side it is
necessary to use a remote control previously stored and
proceed as follows:
1. Power only the control unit to be programmed
2. Activate ADLER programming by holding down buttons 4 and
6 until the 6 LEDs turn on
3. Release the buttons and enter the code 12 11 14.
The two highlighted digits indicate the remote control channel
recorded in the control unit; for channel 1 the digits are 11,
for channel 2 the digits are 12, for channel 3 the digits are
13, etc up to channel 6. Once the codes have been entered,
the LED of the selected channel will blink for 2 minutes after
which it exits programming.
4. Position the roll-up shutter at mid-height using
UP-STOP-DOWN
5. Press and keep pressed - for about 5 seconds - the key PROG
of the transmitter until the motor, moving for 1/2 second in
both the ways, proves it is entering into programming phase.
6. Release the key PROG
7. Press the key UP: the roll-up shutter goes up at normal speed
8. Once in contact with the upper lock, it stops and memorizes
the position
9. To exit the programming mode, wait for the led to switch off
or press key 1 to exit immediately.
To set the upper position of the end-of-stroke sensor
on a roll-up shutter without lock on the upper side, it is
necessary to use a remote control previously stored and
proceed as follows:
Repeat points 1, 2, 3, 4, 5, and 6 described above
7. Position the roll-up shutter in the UPPER position desired using
the UP and DOWN buttons. To regulate it precisely, press the
PROG button when the motor is close to the limit switch. the
motor will start to move in jerks
8. Press the key STOP once reached the required position
9. To exit the programming mode, wait for the led to switch off
or press key 1 to exit immediately.
UPPER
POSITION
MIDDLE
POSITION
LOWER
POSITION
PROGRAMMING OF THE LOWER POSITION
OF THE END-OF-STROKE SENSOR
To set the lower position of the end-of-stroke sensor it is
necessary to use a remote control previously stored and
proceed as follows:
1. Power only the control unit to be programmed
2. Activate ADLER programming by holding down buttons 4 and
6 until the 6 LEDs turn on
3. Release the buttons and enter the code 12 11 15
The two highlighted digits indicate the remote control channel
recorded in the control unit; for channel 1 the digits are 11,
for channel 2 the digits are 12, for channel 3 the digits are
13, etc up to channel 6. Once the codes have been entered,
the LED of the selected channel will blink for 2 minutes after
which it exits programming.
4. Position the roll-up shutter at mid-height using
UP-STOP-DOWN
5. Press and keep pressed - for about 5 seconds - the key PROG
of the transmitter until the motor, moving for 1/2 second in
both the ways, proves it is entering into programming phase.
6. Release the key PROG
7. Position the roll-up shutter in the LOWER position desired
using the UP and DOWN buttons. To regulate it precisely, press
the PROG button when the motor is close to the limit switch:
the motor will start to move in jerks
8. Press the key STOP once reached the required position
9. To exit the programming mode, wait for the led to switch off
or press key 1 to exit immediately.
PROGRAMMING OF THE MIDDLE POSITION
OF THE END-OF-STROKE SENSOR
To set the middle position of the end-of-stroke sensor it is
necessary to use a remote control previously stored and
proceed as follows:
1. Power only the control unit to be programmed
2. Activate ADLER programming by holding down buttons 4 and
6 until the 6 LEDs turn on
3. Release the buttons and enter the code 12 11 16.
The two highlighted digits indicate the remote control channel
recorded in the control unit; for channel 1 the digits are 11,
for channel 2 the digits are 12, for channel 3 the digits are
13, etc up to channel 6. Once the codes have been entered,
the LED of the selected channel will blink for 2 minutes after
which it exits programming.
4. Position the roll-up shutter in the INTERMEDIATE position
desired using UP and DOWN.
5. Press and keep pressed - for about 5 seconds - the key PROG
of the transmitter until the motor proves the correct storage of
the end-of-stroke by moving for 1/2 second in both the ways
6. Release the key PROG
7. To exit the programming mode, wait for the led to switch off
or press key 1 to exit immediately.
To take the roll-up shutter to a middle position press
the key STOP for at least 3 seconds (when the motor is
stopped): the roll-up shutter moves until reached the
position stored.
To delete the intermediate position, it a previously recorded
remote control must be available. Repeat the procedure
indicated above and skip step 4.