Dimensions, Weights; Connection To The Evaluation Unit - Balluff BTL7-P511-M-P-S32/S115/KA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _
Micropulse Transducer in a Profile Housing
7
Technical data (continued)
7.5

Dimensions, weights

Housing height
36.8 mm
Nominal length
50...7620 mm
Weight (depends on length) Approx. 1.4 kg/m
Housing material
Aluminum
BTL7-...-KA_ _
Cable material
PUR
cULus 20549
80°C, 300 V,
internal wiring
Cable temperature
–40°C...+90°C
Cable diameter
Max. 7 mm
Permissible bending radius
Fixed routing
≥ 35 mm
Movable
≥ 105 mm
7.6

Connection to the evaluation unit

The maximum sampling frequency f
current value is available with each sampling, can be found
in the following graphic:
f
in Hz
A,max
Fig. 7-1:
Maximum sampling rate depending on the nominal length
www.balluff.com
, at which a new
A,max
The minimum sampling frequency f
Nominal length in mm
is 62,5 Hz.
A,min
(1) 1 magnet
(2) 2 to 16 magnets
english
17

Publicidad

Tabla de contenido
loading