Technical Data; Accuracy; Ambient Conditions; Supply Voltage (External) - Balluff BTL6-A/C/E/G500-M-PF-S115 Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL6-A/C/E/G500-M-PF-S115 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
10

Technical data

10.1

Accuracy

The specifications are typical values for BTL6-A/C/E/G... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2,
BTL6-A-3801-2, BTL5-F-2814-1S or BTL5-T-2814-1S
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
BTL6-A/G...
BTL6-C/E...
Repeat accuracy
Sampling rate
(dependent on the nominal length)
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 mm
Temperature coefficient
(nominal length = 500 mm, magnet in
the middle of the measuring range)
Max. detectable speed
10.2

Ambient conditions

Operating temperature
Storage temperature
Relative humidity
Shock rating
per EN 60068-2-27
1)
Continuous shock
per EN 60068-2-29
1)
Vibration
per EN 60068-2-6
1)
Degree of protection per
IEC 60529
(when attached)
Individual specifications as per Balluff factory standard
1)
www.balluff.com
350 µV
> 5 µm
700 nA
> 5 µm
≤ ±0.002 % FS
> ±5 µm
Max. 2 kHz
±200 µm
±0.04 % FS
≤ 30 ppm/K
10 m/s
−25°C to +70°C
−40°C to +100°C
< 90%, non-condensing
50 g/6 ms
50 g/2 ms
12 g, 10 to 2000 Hz
IP67
10.3

Supply voltage (external)

Voltage, stabilized
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
10.4

Output

BTL6-A... Output voltage
Load current
BTL6-C... Output current
Load resistance
BTL6-E... Output current
Load resistance
BTL6-G... Output voltage
Load current
Short circuit resistance
10.5

Input

Programming inputs La/Lb
Overvoltage protection
10.6

Dimensions, weights

Housing height
Nominal length
Weight (depends on length)
Housing material
10 to 30 V DC
≤ 0.5 V
PP
≤ 150 mA
≤ 3 A/0.5 ms
Up to 36 V
Up to 36 V
500 V DC
0 to 10 V
Max. 5 mA
0.1 to 20 mA
≤ 500 ohms
4 to 20 mA
≤ 500 ohms
−10 to 10 V
Max. 5 mA
Signal cable to 36 V
Signal cable to GND
10 to 30 V DC
High-active
Up to 36 V
20.8 mm
50 to 4572 mm
Approx. 1 kg/m
Anodized aluminum
english
17

Publicidad

Tabla de contenido