Technical Data; Dimensions, Weights, Ambient Conditions; Supply Voltage (External); Outputs - Balluff BTL5-A/C/E/G1-M-B/Z-DEX-K/KA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
BTL5-A/C/E/G1_-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _
Micropulse Linear Transducer - Rod Style
7

Technical Data

Typical values at DC 24 V, room temperature and BTL5 with nominal length 500 mm. Ready for operation at once.
Full accuracy after warm up. Values are with BTL-P-1013-4R, BTL-P-1013-4S or BTL-P-1012-4R magnet rings or
with BTL2-S-6216-8P-Ex, BTL2-S-5113-4K-Ex, BTL2-S-4414-4Z-Ex or BTL2-S-4414-4Z01-Ex floats.
Repeatability
Voltage
Current
Minimum
Sampling rate:
Nominal length NL
< 1400 mm
> 1400 mm
Non-linearity
Nom. length < 500 mm > 500 mm
in µm
±100
1000
in mV <
nom. length/mm
Temperature coefficient
Voltage output:
[150 µV/K + (5 ppm/K * V)] * ΔT
Current output:
[0.6 µA/K + (10 ppm/K * I)] * ΔT
V = output voltage range in [V]
I
= output current range in [mA]
ΔT = temperature coefficient in [K]
Shock loading
100 g/6 ms
1
per EN 60068-2-27
Continuous shock 100 g/2 ms
1
per EN 60068-2-29
Vibration
12 g, 10 to 2000 Hz
1
per EN 60068-2-6
(avoid resonant frequencies of the
transducer rod)
up to 350 bar
Pressure rating
when installed in hydraulic cylin-
der (zone 1)
1
Individual specifications as per
Balluff factory standard
7.1
Dimensions, weights,
ambient conditions
Nominal length
< 4000 mm
➥ ➥ ➥ ➥ ➥ Fig. 3-1
Dimensions
Weight
approx. 2 kg/m
Housing
Stainless steel
Rod
Stainless 1.4571
Diameter
10.2 mm
Wall thickness
2 mm
Module of elasticity approx. 200 kN/mm
Mounting thread 3/4"-16UNF or M18×1.5
Operating temp. –40 °C to +60 °C
Humidity < 90 %, non-condensing
Protection class per
IEC 60529 IP 67 when closed up
7.2

Supply voltage (external)

Regulated supply voltage
BTL5-_1...
DC 20 to 26 V
Ripple
< 0.5 V
10
english
Current draw < 130 mA + output signal
0.5 mV
Inrush
1 µA
Polarity reversal protection built-in
5 µm
Overvoltage protection
Transzorb diodes
Electric strength
f
Standard
GND to housing 500 V DC
1 kHz
7.3

Outputs

0.5 kHz
BTL5-A11...
Output voltage
Load current
±0.02 % FS
Ripple
< ±2 mV
BTL5-G11...
Output voltage –10...10/10... –10 V
Load current
Ripple
BTL5-C1_...
Output current 0...20/20...0 mA
Load resistance < 500 Ohm
BTL5-E1_...
Output current 4...20/20...4 mA
Load resistance < 500 Ohm
7.4

Cable

5 m long, shielded, axial or radial
orientation. Max. length of signal
transmission 20 m.
The transducer is
certified with IECEx
PTB 11.0035X. The
current issue can be
found at
www.iecex.com
In our accredited EMC Laboratory,
proof has been documented that
these Balluff products meet the
2
EMC requirements of the follow-
ing product standard:
EN 61326-2-3
(noise immunity and emission)
ss
< 3 A/0.5 ms
0...10/10...0 V
< 5 mA
< 5 mV
< 5 mA
< 5 mV
The
transducer
is certified
under KC
certificate
number 13-
AV4BO-0631.
The CE Mark verifies
that our products meet
the requirements of the
current EMC Directive.
Ignition Class "d"
Flameproof enclosure
7.5

Magnet rings

(order separately)
BTL-P-1013-4R, BTL-P-1013-4S,
BTL-P-1012-4R
Installation dimensions ➥ ➥ ➥ ➥ ➥ Fig. 3-5
Weight
approx. 10 g
Material
anodized aluminum
Operating temp. –40 °C to +85 °C
7.6
Floats (order separately)
Material
Stainless steel
Operating temp. –20 °C to +120 °C
Float BTL2-S-6216-8P-Ex
Installation dimensions ➥ Fig. 3-7
Weight
69 g
Pressure rated to 15 bar
Float BTL2-S-5113-4K-Ex
Installation dimensions ➥ ➥ ➥ ➥ ➥ Fig. 3-8
Weight
34 g
Pressure rated to 40 bar
Float BTL2-S-4414-4Z-Ex
Installation dimensions ➥ ➥ ➥ ➥ ➥ Fig. 3-9
Weight
34 g
Pressure rated to 20 bar
Float BTL2-S-4414-4Z01-Ex
Installation dimensions ➥ ➥ ➥ ➥ ➥ Fig. 3-10
Weight
52 g
Pressure rated to 20 bar
Emission tests:
RF Emission
EN 55011
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4

Publicidad