ON TIMER

Select the length of time you want. The unit automatically
starts once the selected time is passes.
(with the unit OFF)
2hour
4hour
CANCELLATION
14hour
PATROLLING FUNCTION
The sensor detects a state requiring attention to room temperature and humidity during operation and tells it with
Patrolling Light. Both "Dry and Low temperature patrolling" and "High temperature and High humidity patrolling"
work. (This function informs a room condition. The unit cannot adjust temperature or lower humidity)
DRY AND LOW TEMPERATURE PATROLLING
It tells that the room is dry or the room temperature is low.
When Patrolling Light turns to red, the unit operates with airflow a little stronger during Intelligent mode (Auto mode).
Patrolling
Light
Humidity / Temperature Mon-
Red
Green
When the room is dry and the room temperature is low, viruses survive more easily. We recommend
that you increase humidity with humidification setting and temperature using heating appliances
according to your room environment.
Material source: Dr. Makoto Shoji, Director of Shoji internal medicine and pediatrics clinic
in Sendai City, Miyagi Prefecture, Japan
Right fig-
Absolute humidity
ure
(1)
Over 11 g
(2)
11 g or less
(3)
7 g or less
*1 The absolute humidity is the total mass of water vapor present in 1 m
and is expressed in g. While humidity generally used for a weather forecast is called relative humidity,
which is the ratio of the partial pressure of water vapor to the equilibrium vapor pressure of water at
a given temperature and is expressed in %. Therefore, the absolute humidity is approximately 8 g at
o
o
15
C and 18 g at 30
C even at the same relative humidity of 60 %.
*2 Survival rate of viruses emitted in air after 6 hours under each environment.
NOTE
• It does not notify of the existence of viruses themselves.
• Patrolling Light's illuminating "Green" does not assure
prevention of infection. Use it as a reference to make an
environment to prevent infection during typical daily life.
KC-G60_50_40EU_OM_WEST.indb 9
6hour
8hour
12hour
10hour
If the beeping sound is set to "ON". (Ref. E-12)
itor
(for 30 seconds)
"%" Light turns on
o
"
C" Light flashing
(Normal)
*1
Virus environment
Environment which is less suitable for
viruses to survive
Environment where viruses can survive
Environment which is suitable for
viruses to survive

OFF TIMER

Select the length of time you want. The unit automatically
stops once the selected time is reached.
(with the unit ON)
1hour
2hour
Beeping sound
Beep (once)
Beep (once)
None
*2
Survival rate
0 % to small per-
cent
5 %
20 %
3
of air regardless of temperature
• While adjusting humidity to approximately 55 % to 65 %
during operation in Intelligent mode (Auto mode), the
unit controls humidification, but does not make changes
according to the virus' environment.
E-9
4hour
8hour
CANCELLATION
Temperature
and humidity
Indoor environment
area (Figure
below)
Dry
(3)
Low temperature
Not dry or low tem-
(1)·(2)
perature
(
Relative humidity (%)
o
C)
2017-08-30 06:33:21

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Kc-g50euKc-g40eu

Tabla de contenido