Important Remarks; Declaration Of Conformity; Technical Specifications - V2 CITY11 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21

IMPORTANT REMARKS

For any installation problem please contact our Customer Service
at the number +39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or wrong
installation.
m
Please read this instruction manual very carefully
before installing and programming your control unit.
• This instruction manual is only for qualified technicians, who
specialize in installations and automations.
• The contents of this instruction manual do not concern the end
user.
• Every programming and/or every maintenance service should
be done only by qualified technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1
(Machinery safety. electrical equipment
of machines, part 1: general rules)
EN 12445
(Safe use of automated locking devices, test
methods)
EN 12453
(Safe use of automated locking devices,
requirements)
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply. The standards require a separation of
the contacts of at least 3 mm in each pole (EN 60335-1).
• After making connections on the terminal board, use one
hose clamp to fix dangerous voltage wires near the terminal
board and another hose clamp to fix safety low voltage wires
used for accessories connection; this way, in case of accidental
detachment of a conducting wire, dangerous voltage parts will
not come into contact with safety low voltage ones.
• The plastic case has an IP55 insulation; to connect flexible or
rigid pipes, use pipefittings having the same insulation level.
• Installation requires mechanical and electrical skills, therefore it
shall be carried out by qualified personnel only, who can issue
the Compliance Certificate concerning the whole installation
(EEC Machine Directive 2006/42/CEE, Annex IIA).
• The automated vehicular gates shall comply with the following
rules: EN 13241-1, EN 12453, EN 12445 as well as any local
rule in force.
• Also the automation upstream electric system shall comply with
the laws and rules in force and be carried out workmanlike.
• The door thrust force adjustment shall be measured by means
of a proper tool and adjusted according to the max. limits,
which EN 12453 allows.
• Connect the earthing lead of the motors to the electricity grid
earth system.
• Observe all necessary precautions (e.g. anti-static bracelet) for
handling parts sensitive to electrostatic discharges.

DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that CITY11 products conform to the
essential requirements established in the following directives:
• 2014/30/EU (EMC Directive)
• 2014/35/EU (Low Voltage Directive)
• Directive ROHS2 2011/65/CEE
Racconigi, 12/01/2010
V2 S.p.A. legal representative.egale della V2 S.p.A.
Antonio Livio Costamagna

TECHNICAL SPECIFICATIONS

Power supply
Max motors load
Max accessories load 24V
Working temperature
Protection fuse
Dimensions
Weight
Protection
- 7 -
230V / 50Hz
120V / 60Hz
700W
700W
10W
10W
-20 ÷ +60 °C
-20 ÷ +60 °C
F1 = 5A delayed F1 = 8A delayed
170 x 185 x 70 mm
1200 g
IP55

Publicidad

Tabla de contenido
loading

Tabla de contenido