Inform the technical service of the incident.
Tilt sensor alarm (error code 0064)
These charging stations are available with a tilt sensor alarm.
Make sure that the unit is installed vertically, perpendicular to the ground. If this is not the case, correct the
installation.
DC current leak (error code 0128)
Depending on the model, charging stations can have a DC current leak sensor for charging. A leak in the current
that causes the alarm to trigger originates from the electric vehicle that is being charged; thus it is not an alarm for
the recharging station, rather the charge is stopped for safety reasons.
The maximum admissible limit for DC current leaks is exceeded.
Charging sequence fault (error code 0256)
Incorrect charging sequence or disconnection of the vehicle during charging. The alarm disappears upon
completing the session.
Maximum permitted charge current (error code 0512)
The vehicle has not respected the maximum charge current allowed during a maximum established time.
The alarm will disappear upon completion of the charge session of the electric vehicle causing the alarm.
Communication failure with the power manager (error code 1024)
Failure in the communication between the station and power manager. This error appears if the station is
configured to work together with a power manager, but it is not present.