Ingeteam INGEREV CITY Ground Manual De Instalacion Y Uso página 51

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting
Connector powered (error code 0008)
Description
The connector is powered when it should not be or is not powered when it should be.
Solution
Measure the voltage present in the connector(s) using a multimeter. Verify that all protections are ON.
If voltage is present
Check that the activation coil of the contactor has a 230 Vac power supply.
If it is powered, the problem may originate from the control card. Make sure that there are no loose or
incorrectly inserted cables in the control card.
If it is not powered, check that there are no loose or incorrectly tightened cables in the contactors or
power relays.
It may be necessary to replace the contactor. Contact the telephone support service.
If no voltage is present
The problem may originate from the control card. Make sure that there are no loose or incorrectly inserted cables in
the control card.
Energy meter communication fault (error code 0016)
Description
The internal communication with the energy meter is not correct or an unmonitored protection has tripped.
Solution
Check the protections and reset them if necessary. If the fault continues, check that the connection is correct.
If the alarm persists, contact the Ingeteam telephone assistance service.
RFID communication fault (error code 0032)
Description
There is an anomaly with the internal communication with the card reader.
Solution
In these charging stations the RFID reader card connects to the control card and the latter to the station's
assembly panel.
ABA2020IQM01_B - Installation and Operation Manual
Ingeteam
EN
ES
FR
IT
51

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ingerev city duo

Tabla de contenido