Carel MasterCella Hoja De Instrucciones página 11

Ocultar thumbs Ver también para MasterCella:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
1. INTRODUCTION
MasterCella is the new electronic controller for static or ventilated refrigerating units, able to manage all the actuators normally featured, such as:
compressors, fans, defrost, alarms and lights. The MasterCella case is IP65 and the electrical wiring is especially simple, due to the fact that the front panel
can be removed. The MasterCella case allows installation either on the panel or on the wall.
2. OPTION CODES
CODE
IRTRRES000
IROPZSEM10
IROPZSEM30
PST00VR100
PSTCON0*00
PSTCONO300
PSTCON1000
PSOPZKEY00
IROPZKEY00
PSOPZKEYA0
IROPZKEYA0
PSOPZPRG00
MDOPZBA000
MDOPZCA000
0402512CEL
0402515CEL
0402517CEL
3. DISPLAY
MasterCella is fi tted with a three digit LED display for the temperature, and icons for displaying the operating status. It can also be connected, using a special
interface, to a further display, used, for example, to show the reading of the third probe.
3.1 Signals on the display
Icon
Function
COMPRESS.
compressor on
VENTILATORE
fan on
DEFROST
defrost in progress
AUX
AUX auxiliary output active
ALLARME
delayed external alarm (before
the time A7' has elapsed)
CLOCK
if at least one timed defrost has
been set
LIGHT
LIGHT auxiliary output active
SERVICE
HACCP
HACCP function enabled
CYCLE
CONTINUOUS CYCLE
function activated
The fl ashing status indicates that the function has been called but cannot be run until the delay timers expire.
DESCRIPTION
small infrared remote control
RS485 serial board
RS485 serial board with automatic recognition of the polarity +/- and connection of repeater display
remote repeater display
connection cables, with one screw end, to the repeater display
Power/ser. connection cables 3 m for repeater display
Power/ser. connection cables 10 m for repeater display
parameter programming key with 12V batteries included
parameter programming key with extended memory and 12V batteries included
parameter programming key with external 230 Vac power supply
parameter programming key with extended memory and external 230 Vac power supply
programming key kit
optional board for 3 relay connectors
optional board for 5 relay connectors
Disconnecting switch 32 A
Shaft H= 85 mm
Yellow/red disconnecting switch
ON
compressor off
fan off
no defrost call
AUX auxiliary output not active
no alarm present
no timed defrost set
LIGHT auxiliary output not active
no malfunction
HACCP function not enabled
CONTINUOUS CYCLE function
not activated
Normal Operation
OFF
compressor call
fan call
defrost call
anti-sweat heater function active
alarms in norm. operation (e.g. high/low
temperature) or alarm from external digital
input, immediate or delayed
clock alarm
anti-sweat heater function active
malfunction (e.g. EEPROM error or probes
faulty)
HACCP alarm saved (HA and/or HF)
CONTINUOUS CYCLE function call
3
Startup
fl ashing
ON if Real-Time
Clock present
+050004105 rel. 1.1 del 17.11.05
Tab.2.a
Tab. 3.a

Publicidad

Tabla de contenido
loading

Tabla de contenido