8.2
DEEP DISCHARGE PROTECTION
Deep discharge protection is activated as soon as the battery voltage falls below a
certain threshold. This protects the battery from damage. The energiser is still switched
on in this battery protection mode, but no more pulses are emitted. The battery must
then be charged externally using the mains adapter supplied.
NOTICE
During the charging of the battery the energiser must be disconnected from the
fence.
8.3
CHARGING THE BATTERY
NOTICE
When charging the battery with the mains adapter, the energiser MUST be
disconnected from the fence! A fully charged battery should be able to power
the fence for about 5‑10 days even without sunlight.
Info
The mains adapter is included in the scope of delivery. It is not possible to
overcharge the battery.
The solar panel charges a flat battery within 2‑3 days. This is only possible if the
energiser is switched off and there is enough sunlight.
8.4
LED INDICATOR
The LED indicator (3) gives you information about the battery status.
ऀ When the battery is fully charged, the energiser cycles at normal speed (every 1.1
sec.) and the LED lights up at the same frequency.
ऀ When the battery voltage is medium, the energiser sends an impulse every 3 sec.
The „ECO mode" is switched on and the LED continues to flash at the same rate as
the pulse. The battery should be recharged.
ऀ If the deep discharge protection is activated, the energiser no longer sends an
impulse and the control LED flashes quickly. In this case the battery must be
recharged with the mains adapter supplied
34
ON
DC
OFF
INSTRUCTION MANUAL VOSS.FARMING SUNNY 800
ON
DC
OFF
42088 | 01 | 2021 | V3