Technical Specifications - Festo CP 11 Manual De Instrucciones

Nodo de bus de campo
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
CP FB11-E
5

Technical specifications

Type
Protection class (as per DIN 40050)
Ambient temperature
Storage temperature
Pin 1 - Operating voltage connection
for electronic components/inputs
• Rated value
(protected against incorrect polarity)
• Tolerance
• Current consumption
Pin 2 - Operating voltage connection
for outputs/valves
• Rated value
(protected against incorrect polarity)
• Tolerance
• Current consumption
Electromagnetic compatibility (EMC)
Resistance to suppression
• tested as per EN 55011
Resistance to interference
• tested as per EN 50082-2
18
CP FB11-E
IP 65
o
o
- 5
... + 50
C
o
o
- 20
... + 70
C
DC 24 V
DC 18 V...30 V
200 mA
DC 24 V
DC 20,4 V...26,4 V)
Sum of all switched
CP solenoid valves
Limit value severity A
9809c

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp fb11-e

Tabla de contenido