Diagramas de flujo de menús – Transmisores modelo 2400S DP
Figura C-6
EDD – Menú de dispositivo
Process Variables
· Mass flow
· Mass flow units
(1)
· Volume flow
(1)
· Volume flow units
· Density
· Density units
· Temperature
· Temperature units
· External pressure input
· Pressure units
(3)
API Process Variables
API volume at reference temperature
· Reference temperature
· Vol flow at ref temp
· Vol total at ref temp
· Vol inventory at ref temp
API batch weighted average
· Average observed density
· Average observed temperature
API other
· Reference temperature
· API CTL
· Density at ref temp
Reset API volume total
Reset API volume inventory
Discrete Events
· Discrete event status
(1) Sólo volumen de líquido.
(2) Disponible sólo si la medición de volumen estándar de gas está habilitada.
(3) Disponible sólo si está instalada la aplicación para mediciones en la industria petrolera.
(4) Disponible sólo si está instalada la aplicación de densidad mejorada.
158
Device >
Device
Totalizers
· Start/stop all totals
· Reset all totals
· Reset all inventories
· Mass total
· Mass inventory
· Mass total and mass inventory unit
· Reset mass total
· Reset mass inventory
· Volume total
· Volume inventory
· Volume total and volume inventory unit
· Reset volume total
· Reset volume inventory
ED Process Variables
Volume at reference temp
· Volume flow rate at ref temp
· Volume total at ref temp
Net mass
· Net mass flow rate
· Net mass total
· Net mass inventory
Net volume
· Net volume flow rate
· Net volume total
· Net volume inventory
Other
· Density at ref temp
· Density in fixed SG units
Concentration
· Density in fixed Baume units
Alarm Status
· Alarm one, bits 1–8
· Alarm two, bits 1–8
· Alarm three, bits 1–8
· Alarm four, bits 1–8
· Alarm five, bits 1–8
· Alarm six, bits 1–8
· Alarm seven, bits 1–8
· Alarm eight, bits 1–8
· Acknowledge all alarms
· Acknowledge alarm
· Reset alarm history
GSV Process Variables
· Gas Std volume flow rate
· Gas Std volume flow total
· Gas Std volume flow inventory
· Gas Std volume flow unit
· Gas Std volume total and inventory units
· Reset gas std volume total
· Reset gas std volume inventory
(4)
(4)
ED Totals
Volume at reference temp
· Volume flow rate at ref temp
· Volume total at ref temp
· Volume inventory at ref temp
· Reset volume total at ref temp
· Reset volume inventory at ref temp
Net mass
· Net mass flow rate
· Net mass total
· Net mass inventory
· Reset net mass total
· Reset net mass inventory
Net volume
· Net volume flow rate
· Net volume total
· Net volume inventory
· Reset net volume total
· Reset net volume inventory
Concentration
· Concentration
· Curve n concentration units
Transmisores modelo 2400S de Micro Motion
continuación
(2)
®
para PROFIBUS-DP