Configuración opcional
Tabla 8-8
Alarmas de estatus y niveles de prioridad continuación
Código
de alarma
Mensaje
A009
Transmitter Initializing/Warming Up
Transmitter Initializing/Warming Up
A010
Calibration Failure
Calibration Failure
A011
Excess Calibration Correction, Zero too Low
Zero Too Low
A012
Excess Calibration Correction, Zero too High Fault
Zero Too High
A013
Process too Noisy to Perform Auto Zero
Zero Too Noisy
A014
Transmitter Failed
Transmitter Failed
A016
Line RTD Temperature Out-Of-Range
Line RTD Temperature Out-of-Range
A017
Meter RTD Temperature Out-Of-Range
Meter RTD Temperature Out-of-Range
A020
Calibration Factors Unentered
Calibration Factors Unentered (FlowCal)
A021
Unrecognized/Unentered Sensor Type
Incorrect Sensor Type (K1)
A029
Internal Communication Failure
PIC/Daughterboard Communication Failure
A030
Hardware/Software Incompatible
Incorrect Board Type
A031
Undefined
Low Power
(2)
A032
Meter Verification Fault Alarm
Meter Verification/Outputs In Fault
(3)
A032
Outputs Fixed during Meter Verification
Meter Verification In Progress and Outputs
Fixed
A033
Sensor OK, Tubes Stopped by Process
Sensor OK, Tubes Stopped by Process
(3)
A034
Meter Verification Failed
Meter Verification Failed
(3)
A035
Meter Verification Aborted
Meter Verification Aborted
A102
Drive Over-Range / Partially Full Tube
Drive Overrange/Partially Full Tube
66
(1)
Prioridad
predeterminada
Ignore
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
Fault
(4)
Varía
Fault
Info
Info
Info
Transmisores modelo 2400S de Micro Motion
Afectada por
Configurable
timeout de fallo
Sí
No
No
No
Sí
No
Sí
No
Sí
No
No
No
Sí
Sí
Sí
Sí
Sí
No
No
No
No
No
No
No
No
No
No
No
No
No
Sí
Sí
Sí
No
Sí
No
Sí
No
®
para PROFIBUS-DP