Earth Connection - GALAGAR GAR AC 180 Manual Técnico De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Screw T should always be in place so as to
avoid deterioration in the equipment due to
negligence in the connection.
The connection to mains is made with the
input hose. This cable has three wires, two of which
are connected to the mains and the other (yellow,
with green border) must be connected to the earth
intake of the plug.
As indicated in figure 4 there are two forms of
connection:
Fig. 4. Forms of connection to electricity mains.
Fig. 4. Forms of connection to electricity mains.
Fig. 4. Forms of connection to electricity mains.
Fig. 4. Forms of connection to electricity mains.
380V POWER LINE
Phase I
Phase II
Phase III
A) Connection to the "power lines"
A) Connection to the "power lines"
A) Connection to the "power lines"
A) Connection to the "power lines"
Phase I
Neutral
B) Connection to lighting line
B) Connection to lighting line
B) Connection to lighting line
B) Connection to lighting line
GAR AC/DC 180. Instructions Manual.
Connection plug

Earth connection

Connection plug
Earth connection
A) Connection to the "power line".
Taking two wires from the electrical "power"
line, we can connect the equipment TWO-PHASE to
380 V.
This connection has the advantage of making
use of the power absorption capacity which the
electrical power lines have.
B) Connection to the lighting line.
Table 2.. Intensities absorbed by the mains (A.C.
welding output) according to the welding electrode
diameters.
ELECTRODE
DIAMETER
(mm)
I1 (Amp)
1,5mm
2,0
2,5
3,25
4,0
Taking a socket outlet from the lighting line we can
connect the equipment SINGLE-PHASE to 220 V.
Make sure the capacity of the installation is sufficient
for the consumption corresponding to the diameter of
the electrode which is going to be used in the welding
operation. (See TABLE 2).
DO NOT FORGET TO CONNECT THE
EARTH INTAKE IN THE SOCKET.
MAKE SURE THE MAINS VOLTAGE
COINCIDES WITH THAT ESTABLISHED IN
THE
MACHINE.
13
MAINS VOLTAGE
220V
380V
I1 (Amp)
10
6
12-14
7-8
20-23
12-13
30-35
17-20
38-42
22-24