Filter Replacement - PLYMOVENT MDB-2 COMPACT Manual De Instalación Y De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 60
To empty the dust drawer, proceed as follows.
Fig. 6.1
• Option: push and hold the
Fig. 5.1B and section 5.2.2) for 5 seconds to activate an
additional cleaning cycle. This will take approx. one minute
per filter cartridge.
• Disconnect the compressed air supply.
• Fully disconnect the unit from the mains.
• Unlock the dust drawer (A) with the supplied square key.
• Gradually open the dust drawer and empty it with an
industrial vacuum cleaner at the same time
• Close the dust drawer and lock it. Make sure to rotate the
key 90°.
• Connect the compressed air.
• Energize the unit.
Fig. 6.1
Emptying the dust drawer
6.3

Filter replacement

max. 2 mm
The control panel indicates by the red light (ref. Fig. 5.1E)
when you must replace the filter cartridges. Replace all filter
cartridges at the same time.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you replace the filter
cartridges.
WARNINg
Do not replace the filter cartridges while the fan is
running.
To replace the filter cartridges, proceed as follows.
Fig. 6.2
• Option: push and hold the
5.1B and section 5.2.2) for 5 seconds to activate a cleaning
>2 mm
cycle. This will take approx. one minute per filter cartridge.
• Disconnect the compressed air.
• Fully disconnect the unit from the mains.
• Loosen the star knob (F) and disassemble the cover plate
(E), the nut (D) and the metal washer (C).
• Remove (one of) the upper filter cartridge(s)
it in the plastic sack in which the replacement filter
cartridge is supplied.
• Seal the sack securely.
• Put a new filter cartridge on the cartridge holder (A) and
attach it with the disassembled parts.
• Do the same procedure for the lower filter cartridge(s).
• Empty the dust drawer with an industrial vacuum cleaner;
refer to section 6.2.
• Connect the compressed air.
• Energize the unit.
• Dispose of the used filter cartridges in accordance with
federal, state or local regulations.
• Clean the environment of the unit.
15. The dust drawer has a pull-out protection. To fully remove it: lift the handle
and pull out the dust drawer.
16. Do not use any liquids to empty or clean the dust drawer; this causes damage
to the filter cartridges.
17. Removing the upper filter cartridge(s) first, keeps the release of dust to a
minimum.
0000104046/150915/0 MultiDust Bank COMPACT
button (ref.
MANUAL CLEANING
.
15 16
A
(ref. Fig.
MANUAL CLEANING button
max. 2 mm
(B) and put
17
>2 mm
A
B
max. 2 mm
Fig. 6.2
Filter replacement
ATTENTION
Make sure that the front of the filter cartridge
aligns
with the filter housing, so that the cover
*)
plate closes well. If this is not the case, the filter
cartridge is not positioned correctly. This can cause
leakage and less efficient operation of the filter
cartridge.
tolerance: max. 2 mm (0.1 in.)
*)
>2 mm
6.3.1
Precoat timer reset
In case of PRECO-N (precoat) on CART-D or CART-C filter
cartridges, you must reset the timer after filter replacement.
This deactivates the filter cleaning system for 30 hours after
filter replacement to maintain the layer of precoat.
ATTENTION
If you do not reset the timer, the lifespan of the
filter cartridges reduces significantly.
C
D
E
F
max. 2 mm
>2 mm
EN - 13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mdb-4 compactMdb-6 compact

Tabla de contenido