To be integrated with a complete reading of the technical speci cations
Positioning and installation
Commissioning done by an approved CAT that issued the guarantee
Air vent in the room
Only the boiler-stove outlet passes through the smoke channel/chimney fl ue
Features of the smoke channel (stretch of duct connecting the boiler-stove to the fl ue/chimney):
a maximum of 3 curves
a maximum of 2 horizontal metres
The exhaust pipes are made of suitable material (recommended: stainless steel)
When using any fl ammable materials (e.g. wood), all precautions have been taken to prevent a fi re hazard
The heating capacity has been appropriately assessed considering radiator effi ciency:
The plumbing system is declared conforming the laws of the country (such as, in Italy, to Ministerial Decree
37, formerly
Law 46/1990) by a qualifi ed technician.
Use
Good quality, dry wood pellets are used
The burner and ash tray must be clean and correctly positioned
The door must be securely closed
The burner must be properly inserted in its seat
The smoke extract duct is clean.
The bleeding process has been applied to the hydraulic system.
The pressure (shown on the pressure gauge) is at least 1,5 bar.
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.

CHECK LIST