LEGEND
ACS:
Household hot water
AF:
Cold Water
AL:
Water supply
B:
Boiler
C:
Fill/Top up
TC
This layout is purely indicative. Have a plumber design and install the system.
ACCESSORIES:
In the diagram shown above, the use of the accessories available on the EDILKAMIN S.p.A. pricelist is assumed.
Individual spare parts are also available (exchanger, valves, etc). For information, please contact your local dealer.
INSTALLATION
CE:
electronic control unit
EV2:
2-way electro-valve
EV3:
3-way electro-valve
NA: Normally Open
NC: Normally Closed
GR:
Pressure reducer
MI:
System in
TC
TC
TC
TC
TC
TC
TC
TC
TC
P:
Pump (circulation)
TC:
RA:
Radiators
V:
RI:
System return
VA:
S:
Drain
Vec:
SB:
Water boiler
VSP:
ST:
Temperature probe
VST:
P
- 64
-
Boiler
Spherical valve
Automatic air vent
Closed surge tank
Safety valve
Thermal discharge valve
DIAGRAM OF THE
HEATING SYSTEM
WITH BOILER WITH
PUFFER
HEATING SYSTEM
WITH BOILER AS THE
ONLY SOURCE OF
HEAT.
HEATING SYSTEM
WITH BOILER COM-
BINED WITH INDOOR
DOMESTIC HOT WA-
TER BOILER.
HEATING SYSTEM
WITH BOILER AS
THE ONLY SOURCE
OF HEATING WITH
PRODUCTION OF
DOMESTIC HOT
WATER BY MEANS
OF BOILER