• Under no circumstances should any foreign substances
be put into the hearth or the hopper.
NEVER use liquid fuel to ignite the boiler or rekindle the
embers.
• Do not use fl ammable products to clean the smoke chan-
nel
(the fl ue section connecting the boiler smoke outlet to the
chimney fl ue).
• Do not clean when hot.
• Whilst the boiler is in operation, the exhaust pipes and
door become very hot (do not touch without using the right
gloves).
• Do not obstruct the ventilation apertures in the room where
the boiler-stove is installed, nor the air inlets of the boiler
itself.
• Do not wet the boiler and do not go near electrical parts
with wet hands.
• Do not use reducers on the smoke exhaust pipes.
• Do not lay laundry directly on the boiler to dry.
Any clothes horse or similar must be placed at a safe
distance from the boiler-stove (danger of re).
THE BOILER MUST NEVER BE MADE TO OPERATE
WITHOUT WATER IN THE SYSTEM.
IT CAN BE DAMAGED IF IT IS IGNITED WITH NO
WATER IN THE SYSTEM.
MUST BE MADE WITH A PRESSURE OF ABOUT 1.5
BAR.
• The main risks that may derive from using the boiler
pertain to non-compliance with installation instructions,
direct contact with live electrical parts (internal), contact
with the fi re or hot parts, when extraneous substances or
non-recommended fuel are introduced, or due to incorrect
maintenance or by repeatedly pressing the ignition button
without having emptied the burner.
• In order to function correctly, the boiler must be installed
in accordance with the instructions given herein and the
door must not be opened during operation: combustion is
fully automatic and requires no intervention.
• Only use certifi ed, high quality, 6/8 mm diameter wooden
pellets for fuel.
• Make sure the boiler is installed and ignited the fi rst time
by Edilkamin-qualifi ed CAT personnel (technical assistan-
ce centre) in accordance with the instructions provided
here within; this is an essential requirement for the valida-
tion of the guarantee.
SAFETY INFORMATION
- 60
• The boiler must be installed in a room that is suitable for
fi re prevention and equipped with all that is required (po-
wer and air supply and outlets) for the boiler to function
correctly and safely.
• The appliance is not designed to be used by people,
including children, with reduced physical, sensorial or
mental abilities. Children must be supervised to ensure
they do not play with the appliance.
• Hearth and hopper components must only be cleaned
with a vacuum cleaner.
• The boiler must not function if the door is open, if the
pellet-loading port is open.
• In the event that the water used for fi lling and toping
up has a hardness greater than 35° F, use a water softener.
For suggestions please refer to regulation UNI 8065-1989
(Water Treatment In Heating Systems For Civil Use).
• Should components fail, the boiler is equipped with safe-
ty devices to guarantee its automatic shutdown.
These are activated without any intervention required.
• It must not be used as a step ladder or a base on which to
rest any object.
• Do not place anything, which is not heat resistant near
the boiler.
• Whilst the boiler is in operation, the exhaust pipes and
door become very hot (do not touch without using the right
gloves).
• Do not obstruct the ventilation apertures in the room where
the boiler-stove is installed, nor the air inlets of the boiler
itself.
• Do not wet the boiler and do not go near electrical parts
with wet hands.
• Do not use reducers on the smoke exhaust pipes.
• The boiler must be kept in a room where the temperature
is above 0 °C.
• Use appropriate anti-freeze additives for the water of the
system.
-