Erreka VIVO-I103 Guía Rápida De Instalación Y Programación página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Operator connections for sliding gates and up-and-over doors
Operator connection
Single encoder
connection (C701)
Connector E1:
V+:
red wire
GND: white wire
SGN1: green or blue
wire
SGN2: do not connect SGN2: closing (FCC)
In sliding gates (C302) and up-and-over doors (C303) it is only possible to use a single
motor (M1), which should be connected to the "MOTOR 1" cable connectors.
When using a single encoder (C701, C704) or dual encoder (C703), always connect it to
the "ENCODER 1" cable connectors.
When using limit switches (C702, C704 or C705), always connect to the "ENCODER 2"
cable connectors.
(parameters C302 and C303)
G1: open
G2: close
G3: common
DS9: SNG1 LED (encoder) E1
DS12: SNG2 LED (encoder) E1
DS1: SNG1 LED (FCA/ATS) E2
DS4: SNG2 LED (FCC/NA) E2
A1:
operator 1
E1:
"ENCODER 1" cable connectors
E2:
"ENCODER 2" cable connectors
Limit switches
connection (C702)
Connector E2:
Connector E1:
V+:
do not connect V+:
GND: common (COM) GND: white wire
SGN1: opening (FCA) SGN1: green or blue
SGN2: purple wire
DS9
DS1
DS4
DS12
G1
G2
G3
Connector E2:
V+:
GND: common (COM)
SGN1: ATS operator safety micro and NA
SGN2: bridge with GND
Dual encoder
FC and single encoder connection (C704)
connection (C703)
Connector E1:
red wire
V+:
GND: white wire
SGN1: green or blue
wire
SGN2: do not connect SGN2: closing (FCC)
DL27
ATLAS Connection (ATS) G6xxI (C705)
do not connect
closing micro (parallel connection)
Connector E2:
red wire
V+:
GND: common (COM)
SGN1: opening (FCA)
wire
VIVO-I203:
VIVO-I203M:
Do NOT
connect the
capacitor in
the motor.
P294Z4
do not connect
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vivo-i103mVivo-i203Vivo-i203m

Tabla de contenido