D1 D2 Parameter
C
0
Number of operators
1
Operator 1 turning direction
(operator 2 also changes)
2
Operator 2 turning direction
(operator 1 also changes)
3
Type of gate
4
O p e n i n g
s a f e t y
(photocell)
5
Closing safety device (photocell)
Closing photocell with C520 or
C521, also prevents the start of
gate opening
6
Electrolock / electromagnet
C630 and C640 are used to
manage an external relay at
24Vdc, connected to cable
c o n n e c t o r s P 1 1 - P 1 2 . T h e
e l e c t r o m a g n e t
externally supplied (through this
relay) and sized in line with the
electromagnets used.
7
Encoder / Limit switches
The connections depend on the
type of operator selected (C301,
C 3 0 2 o r C 3 0 3 ) ; s e e t h e
corresponding wiring diagram)
8
Radio card
9
Safety strip
A
Slowdown
P
1
Total opening radio programming
2
P e d e s t r i a n o p e n i n g r a d i o
programming
3
Gate open/close programming
F
1
Key command using ST1 and
ST2 pushbuttons.
Wi th F101 the gate (total or
pedestrian) can be kept open by
keeping ST1 or ST2 pressed down
respectively. This allows the time
scheduler to be used in combination
with F2 and/or F4 K 00.
2
A u t o m a t i c o r s t e p - b y - s t e p
operation mode and standby
time (in seconds) in automatic
mode
3
Pedestrian opening (%)
4
Pedestrian closing mode
Complete programming table (I)
D3
D4
0
1, 2
0
1, 2
0
1, 2
0
1...3
0,1
0,1
d e v i c e
0...2
0,1
0...4
0...4
m u s t
b e
0
0...5
0
1, 2
0
1, 2
0
0...3
o
ç
o
ç
o
ç
0
0...4
0..5.
0...9
0...9
0...9
0...5
0...9
Pre-set
Options or values
option
01
01: one operator,
(VIVO-I103)
02
02: two operators (only available with C301)
(VIVO-I203)
01
01: direction A, 02: direction B. Check direction by
pressing UP (open) and DOWN (close)
01
01: direction A, 02: direction B. Check direction by
pressing UP (open) and DOWN (close)
01
01: swing, 02: sliding, 03: up-and-over
00
00: not installed,
10: no testing, 11: with testing
00
00: not installed,
10: no testing,
11: with testing,
20: no testing,
21: with testing
00
00: not installed
1X: electrolock
Programmable electrolock time: 3 seconds
with X=0 (by default), 3.5s with X=1, 4s with
X=2, 4.5s with X=3, 5s with X=4.
2X: electrolock
Programmable time (electrolock/motor
reverse): 4.5/1.5 seconds with X=0 (by default),
5/2s with X=1, 5.5/2.5s with X=2, 6/3s with
X=3, 6.5/3.5s with X=4.
30: electromagnet without impulse
40: drop electromagnet
00
00: not installed; 01: with single encoder;
02: with limit switches;
03: with dual encoder;
04: with encoder and limit switches (not available
with C301 selected);
05: VULCAN VUS and ATLAS (ATS) G6xxI (only
available with C301 or C303 selected)
02
01: RSD card (non-decoding);
02: two-channel decoder card
01
01: mechanical; 02: resistive 8k2
01
00: no slowdown;
01: slowdown in opening and closing;
02: slowdown in opening;
03: slowdown in closing
Programmes total opening code and channel
Programmes pedestrian opening code and channel
Programmes the operations in accordance with
configuration CA
01
00: ST1 and ST2 without effect, key commands are
made by radio (channel 1: total opening-
closing, channel 2: pedestrian opening-closing)
01: ST1 total opening-closing, ST2 pedestrian
opening-closing
02: ST1 total opening, ST2 total closing
03: dead-man mode (the display shows HP);
04: dead-man mode in closing
00
00: step-by-step mode
01: automatic mode and stand-by time 1 second;
...
59: automatic mode and stand-by time 59 sec.;
1.0: 1 min. 0 sec.;
...; maximum 4 minutes
40
00: pedestrian opening is not carried out,
10: 10% of the total opening, etc
00
00: step-by-step mode
01: automatic mode and stand-by time 1 second;
...
59: automatic mode and stand-by time 59 sec.;
1.0: 1 min. 0 sec.;
...; maximum 4 minutes
without
reverse
impulse.
with
reverse
impulse.
23