D1 D2 Parameter
A
0
Flashing light
1
Garage light time
2
Gate speed
3
Slowdown speed
5
Reverse after closing (prevents the
operator from seizing up on the
stopper)
6
Maximum entrapment current
(each value equivalent to 0.5A)
Digit D3 can be used to set current
to normal speed;
Digit D4 can be used to set current
to slow speed
7
Crossing over photocell (opening
or closing) during stand-by (in
automatic mode only)
8
Effect of ST1-ST2 pushbuttons
during stand-by time (in automatic
mode only)
9
Opening mode
A
Lapse between leaves in opening
and closing
b
Using the EPS1 card connector
For parameters Ab02 and Ab03,
use the EPS1 card and bridge the
network input cable connectors
instead of connecting them to the
network (see "Brake connection"
diagram).
C
Hydraulic pressure maintenance
d
Hammer
E
Special functions
N
0
Programming lock key
Be sure to remember any key used,
f o r f u t u r e a c c e s s t o t h e
programming
1
Total operations completed
2
Partial operations completed
t
0
FTP communication
1
GSM signal strength
24
Complete programming table (and II)
Pre-set
D3
D4
option
0
1, 2
0...5. 0...9
0
1...9
0
1...9
0
0...5
0...9
0...9
0
0...2
0
0...2
0
1...3
0...9
0...9
0
0...3
0
0...6
0
0,1
0
0...2
0
0,1
X
X
X
X
O
ç
X
X
Options or values
01
01: without pre-warning
02: with pre-warning
03
03 = 3 sec.; 59 = 59 sec.; 2.5 = 2 min. 50 sec.;
....; maximum 4 minutes
03
01: minimum speed (40Hz);
02: 45Hz, 03: 50Hz, 04: 55Hz, ...;
09: maximum speed (80Hz)
03
01: minimum speed (21Hz);
02: 22Hz, 03: 23Hz, 04: 24Hz, ...;
09: maximum speed (29Hz)
00
00: no reverse;
...;
05: maximum reverse
00
00: disabled;
01: disabled at normal speed and 0.5A at slow
speed;
10: 0.5A at normal speed and disabled at slow
speed;
....;
65: 3A at normal speed and 2.5A at slow speed;
...;
99: 4.5A at normal and slow speed
02
00: does not affect stand-by time
01: immediate close when the photocells are
released
02: restarts standby time
02
00: have no effect during stand-by
01: produce immediate closing
02: restart stand-by time
02
01: collective opening
02: step-by-step alternative stop
03: automatic alternative stop (if F200 is
selected, A903 becomes A902)
22
00: no lapse in opening or closing (apply only in
gates with no overlap);
XY: X lapse in opening
(X=1: 1 second, ... , X=9: 9 seconds)
Y lapse in closing
(Y=1: 1 second, ... , Y=9: 9 seconds)
00
00: use for standard traffic light;
01: use for brakes
02: NC contact with gate open (L1-COM) and
gate closed (L2-COM)
03: impulse 1 second Open (L1-COM) when
starting opening and Close (L2-COM) when
starting closing. Allows another panel to be
enabled.
00
00: no pressure maintenance;
01: every 0.5 hours; 02: every 1 hour;
03: every 2 hours; 04: every 6 hours;
05: every 12 hours; 06: every 24 hours
00
00: no hammer; 01: with hammer
00
00: no special function;
01: opening photocell C4 programmed for
pedestrian crossing;
02: industrial;
0000
The preset option is 0000 (no key). If any figure is
changed, this is considered key.
Select the required key (starting with D1) using
UP and DOWN. Press ESC to cancel or ENTER to
confirm and move to D2, and so on.
Indicates the hundreds of cycles completed (for
example, 68 indicates 6800 cycles completed)
Indicates the hundreds of cycles completed. It can
be reset by pressing ST1, ST2 and ENTER
simultaneously.