SPECIFICATIONS

Measurement Range
Measurement Accuracy
Measurement Repeatability
Distance-To-Spot (D:S) Ratio
Emissivity
Response Time
Display Type/Size/Resolution
Laser Class/Power/Wavelength
Response Wavelength
Auto Power Off
Thermometer Battery Life
Current Consumption
Operating Temperature
Storage Temperature
Dimensions
Weight
Power Source
-22° to 482°F (-30° to 250°C)
±3°F (2°C) or 2% of reading
(whichever is greater) above 32°F
(0°C); ±5°F (3°C) or 2% of reading
(whichever is greater) below 32°F
1% of reading or 1°C
6:1
Adjustable from 0.1 to 1 in 0.01
increments (factory set to 0.95)
500 msec for 95% response
LCD/1.0 x 0.8 in.
(25 x 19mm)/±0.1°C
Class II/<1mW/630 to 660nm
8 to 14 um
After 15 seconds of inactivity
50 hours, typical
<5mA w/laser off
32° to 104°F
(0° to 40°C)@<75% R.H.
-4° to 140°F
(-20° to 60°C)@<85% R.H.
4.25 x 2.05 x 0.98 in.
(108 x 52 x 25mm)
1.41 oz. (40g)
Two CR2032 (3V) non-
rechargeable Lithium-ion cells