Idiomas disponibles

Diagrama de Cableado de Sistema AC (60K 1 fase)
OFM
TYPE
ADJ
ON
0
ON
0
IFM
1 2 3
1
1
1 2
A B C
D E
NOTES:
* Default factory settings.
1: Remove the red lead from
240V terminal and then connect the red lead to
2: switch
TYPE and
ADJ
choose different model and air volume . please refer to the user manual to choose
3:
W2 wire is not provided in some models and
B is only for HP unit .
4:
MANUAL DEFROST
and
JUMP
is unavailable for AC unit.
PLUG PLATE
T1
T2
CC
L2
L1
LED1
C
YOUT
TDC
O FAN
CN8
0 1
AD
CN18
0 1
CN14
RED
CN18
JUMP
BLACK
0
L1
MANUAL DEFROST
T4
C RV CN15
T
3
208V terminal on the transformer for 208 volts.
0
or
1 .
GND
L
1
L2
R
LINE VOLTAGE
FACTORY STANDARD
FIELD INSTALLED
C
FACTORY OPTIONAL
WHITE
D
LOW VOLTAGE
FACTORY STANDARD
GREEN
G
FIELD INSTALLED
FACTORY OPTIONAL
YELLOW
USE COPPER CONDUCTORS ONLY
Y
WARNING
BLUE
B
CABINET MUST BE PERMANENTLY
W2
GROUNDED AND ALL WIRING TO CONFORM TO
WHITE/BLACK
I.E.C, N.E.C, C.E.C, C.L.C, AND LOCAL CODES AS APPLICABLE
6
REPLACEMENT WIRE MUST BE THE SAME GAUGE AND
1
5
INSULATION TYPE AS ORIGINAL WIRE.
4
CN2
3
2
1
CN16
CC
COMPRESSOR CONTACTOR
COMP COMPRESSOR
TDC
TIME DELAY CONTROL
T4
10K RESISTANCE.
T3
10K RESISTANCE.
HPC
SHORT CIRCUIT WIRE
LPC
SHORT CIRCUIT WIRE
OFM
OUTDOOR FAN MOTOR
RC 1
COMPRESSOR RUN CAPACITOR
RC 2
OUTDOOR FAN MOTOR RUN CAPACITOR
GND
GROUND CHASSIS
IFM
INDOOR FAN MOTOR
STEADY ON = NORMAL OPERATION
0
OFF = TDC FAILURE
1 FLASH = T3 SENSOR FAILURE
1
2 FLASH = T4 SENSOR FAILURE
2
3 FLASH = LPC OPEN
3
5FLASH = IFM FAILURE
5
6FLASH = HPC OPEN
6

Hide quick links: