Diagrama de Cableado de Sistema HP (60K 1 fase)
OFM
TYPE
ADJ
ON
0
ON
0
IFM
1 2 3
1
1 2
1
A B C
D E
* Default factory settings.
notes:
1: remove the red lead from
240v terminal and then connect the red lead to
2: switch
TYPE and
ADJ
choose different model and air volume . please refer to the user manual to choose
3:
w2 wire is not provided in some models.
4: switch
JUMP and
MANUAL DEFROST
choose different defrost logic . please refer to the user manual to choose
PLUG PLATE
T1
T2
CC
L2
L1
LED1
C
YOUT
DFC
O FAN
0 1
CN8
AD
CN18
0 1
CN14
JUMP
RED
0
1
CN18
BLACK
L1
MANUAL DEFROST
T4
C RV CN15
T
YELLOW
RV
208v terminal on the transformer for 208 volts.
0
or
1
0
CC
GND
CCH
COMP COMPRESSOR
DFC
L1
T4
T3
L2
HPC
LPC
OFM
CCH
RC 1
RC 2
RV
GND
HGS
R
JUMP
IFM
C
MANUAL DEFROST 1 AUTO DEFROST/ 0 MANUAL DEFROST
WHITE
D
LINE VOLTAGE
FACTORY STANDARD
GREEN
G
FIELD INSTALLED
FACTORY OPTIONAL
YELLOW
Y
LOW VOLTAGE
BLUE
FACTORY STANDARD
B
FIELD INSTALLED
W2
WHITE/BLACK
FACTORY OPTIONAL
C COM
6
USE COPPER CONDUCTORS ONLY
W2
WARNING
5
W1
CABINET MUST BE PERMANENTLY
4
3
RED
GROUNDED AND ALL WIRING TO CONFORM TO
2
I.E.C, N.E.C, C.E.C, C.L.C, AND LOCAL CODES AS APPLICABLE
1
REPLACEMENT WIRE MUST BE THE SAME GAUGE AND
CN16
INSULATION TYPE AS ORIGINAL WIRE.
0
1
2
3
5
or
1 .
6
COMPRESSOR CONTACTOR
CRANKCASE HEATER
DEFROST CONTROL
AMBIENT
HIGH PRESSURE CUT-OUT CONTROL
LOW PRESSURE CUT-OUT CONTROL
OUTDOOR FAN MOTOR
COMPRESSOR RUN CAPACITOR
OUTDOOR FAN MOTOR RUN CAPACITOR
REVERSING VALVE
GROUND CHASSIS
HOT GAS OR COMPRESSOR TOP SENSOR
DEFROST JUMP 1 NORMAL TIME / 0 30MINUTE
INDOOR FAN MOTOR
STEADY ON = NORMAL OPERATION
OFF = DFC FAILURE
1 FLASH = T3 SENSOR FAILURE
2 FLASH = T4 SENSOR FAILURE
3 FLASH = LPC OPEN
5FLASH = IFM FAILURE
6FLASH = HPC OR HGS OPEN