Descargar Imprimir esta página

Peavey PROBASS 500 Manual De Operación Y Uso página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

R R e e a a r r P P a a n n e e l l
27
28
29
27 ground polarity switch
The ground switch is a 3-position‚ rocker-type switch. Under normal operation it should be in the center (zero)
position. If hum or noise is present with the ground switch in the center position‚ place the ground polarity
switch to positive or negative (+ or -) to minimize hum. Should a problem continue‚ consult your authorized
Peavey dealer‚ the Peavey factory or a qualified service technician. Note: The ground switch is not functional on
220/240 Volt models.
28 reset/circuit breaker switch
Use this switch to restore power to the unit when the internal breaker is tripped. Turn the power switch to the
off position before resetting the breaker. To reset‚ push the reset button in and release it. Turn the unit back on
and confirm that the power LED is on. If the breaker is tripped again upon power-up‚ consult your authorized
Peavey dealer‚ the Peavey factory or a qualified service technician.
29 IEC connector/detachable line cord
For your safety‚ we have incorporated a detachable‚ 3-wire line (mains) cord with proper grounding facilities. It
is not advisable to remove the ground pin under any circumstances. If it is necessary to use the amp without
proper grounding facilities‚ a suitable grounding adapter should be used. Refer to the back of your amp for the
proper voltage requirements before connecting to a power receptacle.
30 speaker output jacks
There are two 1/4" jacks and one Neutrik type jack that provide the powered signal from the amplifier. Each
connector is electrically the same (parallel). Use one of the jacks to connect your speaker cabinet and the other
to add a second speaker cabinet in parallel. The minimum speaker load impedance is 2 Ohms or two 4 Ohm
speakers in parallel.
Warning: To prevent the amplifier from overheating‚ the front and rear fan vents should remain clear of
obstructions.
31 power amp input
Used to connect a line level signal to the power amplifier (i.e. external preamp). This jack‚ when used‚
disconnects the internal preamp.
32 preamp out
The preamp output can be used to route the amplified signal to a mixing console‚ tape recorder or other device.
Connect the preamp output using a shielded cable to an input of one of these devices. This does not affect the
operation of the amplifier. The preamp out and power amp in jacks can also be used as a line level effects patch
point.
33 remote jack switch
Provided for an optional footswitch. Allows remote selection of the input mute and the effects loop. Mute switch
on front panel must be depressed to the IN position for the footswitch to function properly.
34 effects return
Input for returning signals from an external low-level effects device or signal processing unit.