Astralpool OPTIMA PRO Manual De Instalación página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
Paragraph 13 – Password
Programming
PROG
-
-
Password
****
Password
0000
-
Paragraph 14 – Flow Alarm
Programming
PROG
-
-
Alarms
Alarm Flow
Flow
Off
Off
Alarm Flow
On
-
Alarm Flow - On
Signals
Alarms
Flow
Paragraph 15 – Level Alarm
Programming
PROG
-
-
Alarms
Level
Stop
-
Paragraph 16 – Flow Display Unit
Programming
PROG
-
-
Unit
Standard
-
EM00136078
-
+
-
+
-
-
+
6
ESC
Off
-
Alarm Level
Stop
-
Alarm Flow
Alarm
ESC
Alarms
Level
Alarm
-
Unit
Standard
<-
-
+
Unit
L/h
-
By entering the password, you can enter the programming
menu and see all the set values. The password will be
requested whenever you seek to modify them.
The flashing line indicates the number than can be
modified. Use the
9), and the
key to select the number to be modified.
Confirm by pressing the
(default), the password is eliminated.
This makes it possible to activate (deactivate) the flow
sensor.
When activated (On), press the
request for the number of signals that the pump waits for
before an alarm is triggered. The number flashes when you
press the
key, and you can then use the
keys to set the value. Confirm by pressing the
Press
to return to the main menu
This makes it possible to set the
sensor alarm is activated. In other words you can decide
whether to stop dosage (Stop) or simply activate the alarm
signal without stopping dosage.
Changes can be made by pressing the
the
keys to set the alarm type. Confirm by
pressing the
key. Press
menu
This
makes it possible to set the dosage unit of
measurement on the display.
Changes can be made by pressing the
the
keys to set the unit of measurement,
choosing between L/h (liters/hour), Gph (Gallons/hour),
ml/m (milliliters/minute) or standard (% or frequency,
depending on settings). Press
the main menu
rev. 2.6
Operation
key to select the number (from 1 to
key. By setting "0000"
Operation
key to access the
Operation
pump when the level
key, then using
to return to the main
Operation
key, then using
to confirm and return to
key.
10

Publicidad

Tabla de contenido
loading

Tabla de contenido