Paragraph 8 – Timed Dosage (Frequency signal input "TRIGGER" activated)
Programming
PROG
Configuration
Configuration
Pump functions
-
+
Pump functions
Time
-
Time
-
Quantity
100ml
-
Time
g.hh.mm
-
Delay
0.01.50
-
Time
g.hh.mm
-
interv.
0.01.50
Trigger Mode
-
N. Open
Pause Input Mode
-
Trigger Mode
Display during Operation
Operating mode
Timer
Alarms and statuses
Liv = level alarm
Flow = flow alarm or
....Release wait
EM00136078
After receipt of the
that can be programmed in ml. It is possible to set a delay time before
the dosing (Delay) and the interval between subsequent dosings
(Interv.) as illustrated in the diagram:
By setting for example an Interval. time = 0, a system is obtained in
which the programmed quantity is dosed after each TRIGGER signal
(with any delay that has been set):
+
+
+
It is possible to start the dosing by pressing the + key, which, in
practice, simulates the Trigger signal.
Trigger Mode
-
N. Open
The Trigger signal can be set to N. Open (it is activated when the
input passes from the open to the closed mode) or to N. Closed (it is
Trigger Mode
-
activated when the input passes from the closed to the open mode).
N. Closed
The Trigger signal is locked during dosing (its receipt is neither stored
nor managed).
Trigger Mode
Disable
The Pause (Remote input) input cannot be programmed and its
activation stops the dosing, while its further deactivation makes the
system wait again for the Trigger signal for a new dosing.
The dosage frequency can be modified while the pump is operating,
by pressing the
frequency, or the
FLOW
sensor status
F
F F
Timer
7,0 ml
Stop
P 0%
Pump status
Dry = pump starting up
Stop = pump stop
Restart = pump restart
TRIGGER signal set, the pump doses a quantity
Trigger
Delay
Trigger
Delay
Programmed value
Quantity in ml
Value of the dosing in
progress
Percentage of
strokes/min
max
rev. 2.6
Operation
Quantity
Interv.
Release
Ritardo
keys at the same time to increase the
keys to decrease it.
Display during Setting (MODE key)
Operating mode
The following are shown in sequence:
quantity to dose, delay in d.hh.mm.
and interval in d.hh.mm
Q.tà
20,0ml
20,0ml
P 100%
Value of the dosing percentage,
which can be modified by
pressing the + or – keys
Dosing value
Programmed
quantity in m
l
7