For Best Results

Start the rangehood several minutes before cooking to develop proper airflow. Allow the rangehood to oper-
ate for several minutes after cooking is complete to clear all smoke and odors from the kitchen.
Button
Function
L
Turns the lights On/Off.
Hood Down / Extended
Press for 2 seconds to raise the Hood.
Press briefly to turn the Motor On/Off.
T1
Hood Near Ceiling
Press once: The Hood lowers.
Press a second time: The Hood Stops.
When the movement has been completed the motor turns on at Speed two.
Warning: The Hood controls only control the Hood functions. The Lighting unit has a completely separate power supply
and a separate switch.
THE ELECTRONIC CONTROL SYSTEM RECOGNIZES AND SIGNALS TWO TYPES OF FAULT.
Led T1
Current absorption threshold exceeded:
If an overload condition occurs, the fault is signalled by LED T1 on the keyboard flashing once every
Slow flashing
2 seconds. Check that nothing is blocking normal hood movements.
The signal remains active until a new hood open/close command is given.
Hood opening safety microswitch tripped:
If the safety microswitch trips, the fault is signalled by LED T1 on the keyboard flashing quickly
(once every 250 ms). This means that the hood has passed the microswitch........ Call Technical
Rapid flashing
Assistance!
You can continue to use the hood's light and motor functions while this fault is active. Whenever the
motor is on, LED T1 will continue to flash, indicating that the fault is still present.