23 - OPTION RELAY OUTPUT
The unit has three relay outputs with normally open dry contact
that can be configured with different functions through the
parameters
,
and
REL1
REL2
The outputs REL1 and REL2 are for generic use (maximum current
5A - 250V) while the output REL3 is primarily intended for driving
the electronic brake of the motor (16A - 250V).
In this table are the available functions and the value to set for the
parameters REL1, REL2 and REL3
FUNCTION
REL1 REL2 REL3
Lock
Opening command
Closing command
Service reporting
Electric brake control
Safety devices test
Custom
Courtesy light
Connect the device controlled by the REL1 output to terminals
Z4 - Z3
Connect the device controlled by the REL2 output to terminals
Z6 - Z5
Connect the device controlled by the REL3 output to terminals
B2 - B1
m
The relay outputs act as simple switches and do not
provide any power supply.
The power supply to the device V
the unit or the line.
If you use the power supply of accessories, 24 Vac or
12 Vdc, make sure that the current required is compatible
with that supplied by the unit.
OUTPUT
V
SUPPLY
V
SUPPLY
a
parameter
DEFAULT =
REL1
a
parameter
REL2
REL3
VALUE
•
SERR
•
APRE
•
CHIU
•
SERV
•
FR.NO
FR.NC
•
•
TEST
•
•
CUST
•
•
•
LUCI
can be provided by
supply
Z6
Z5
Z4
Z3
Z2
Z1
REL2
REL1
(courtesy light)
LUCI
DEFAULT =
(no function)
NO
23.1 - COURTESY LIGHT
The courtesy lights can be operated in the following ways:
1. Timer control
The lights turn on when the opening is commanded and stay
on for the time set.
Select the value
T.LUC
desired time.
2. Moving + timer
The lights turn on when the opening is commanded; when the
door stops (open or closed) the lights stay on for the time set.
Select the value
CICL
desired time.
3. Timer by AUX control
The lights are activated by a remote control stored on channel
4 of the MR receiver and stay on for the time set.
Select the value
TIM
desired time.
4. Light monostable
The lights are activated by a remote control stored on channel
4 on the receiver MR and stay on for the whole duration of
the command transmission.
Select the value
MONO
5. Light bistable
The lights are activated by a remote control stored on channel
4 of the receiver MR: a first command turns on the lights, a
second command turns them off.
Select the value
BIST
6. Bistable + timeout
The lights are activated by a remote control stored on channel
4 of the MR receiver and stay on for the time set.
A second transmission before time runs out turns off the
lights. Select the value
set the desired time.
23.2 - LOCK
The relay is closed for three seconds each time a new opening
manoeuvre is started.
The operation of the electric lock can be supported with the
following functions:
1. Backlash: before start opening the door is controlled to close
for a short time to facilitate the unlocking of a lock.
To activate this function, set the backlash time through
the
T.AR
2. Final closure stroke: after closing the door is still driven for a
short time at full power to facilitate the enabling of a lock.
To activate this function, set the final closure stroke through
the parameter
T.CVE
- 42 -
in the parameter
and set the
LUCI
in the parameter
and set the
LUCI
in the parameter
and set the
AUX
in the parameter
AUX
in the parameter
AUX
in the parameter
TOUT
AUX
and