9. User is prompted for a Fresh Air Setup (FAS):
"SET", "?" icon and FAS display.
If Fresh Air Setup is desired, immediately press the TEST button.
"HOURGLASS", "SET", and FAS display.
If user does not desire FAS, do NOT press the TEST button:
The instrument continues the ON sequence.
NOTE: When performing a fresh air setup, the instrument must
be in a known clean air. The fresh air setup has limits.
If a hazardous level of gas is present, the ALTAIR Pro
instrument displays "FAS / ERR".
Press the TEST button to acknowledge the error. and
perform an instrument calibration.
10. If the instrument was configured for Oxygen, it displays:
Oxygen reading
% icon
battery indicator.
If the instrument is configured for a toxic gas, it displays:
gas reading
PPM icon
battery indicator.

Battery Life Indicator (See FIGURE 2-2)

The battery condition icon continuously displays in the upper right-
hand corner of the display.
As the battery is depleted, battery icon segments go blank until
only the outline of the battery icon remains.
Each battery indicator segment represents approximately
1/4 of the total battery capacity.
2-6