Icemaker
Liquid Line
Suction Line
5/8" ID
Fig. 9
3. An electrical link/connection between the
icemaker and compressor system is NOT
necessary. Where a multi compressor rack
system is used, the icemaker's internal controls
will close the electrically operated solenoid
valves to stop ice production. Where a single
remote compressor is used, this must be fitted
with a low pressure safety switch to stop the
compressor at approx. 0.5 bar suction pressure
as the solenoid valve's closing will result in the
compressor pumping down.
2) After completing all the refrigeration tubing
connections, the pipe work should be leak
tested, evacuated and vapour charged with
R404A. The design pressure of R404A is 31.4
bar (3.08 MPa) at discharge side and 16.7 bar
(1.64 MPa) at suction side.
3) The refrigeration connections are now complete.
Proceed to sections 4 and 5 to continue with
other service connection requirements before
completing section 6, the start-up procedure.
4) Refit the side and top panels in their correct
positions.

4. ELECTRICAL CONNECTIONS

WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets
t h e n a t i o n a l a n d l o c a l e l e c t r i c a l c o d e
requirements. To prevent possible severe
3/8" ID
Expand
Liquid Line
Suction Line
electrical shock to individuals or extensive
damage to equipment, install a proper earth
wire to the icemaker. Disconnect the main
power supply before any maintenance, repairs
or cleaning is undertaken.
* T h i s a p p l i a n c e r e q u i r e s a s e p a r a t e 2 2 0 -
240VAC, 12A supply. The electrical supply must
be protected by a suitable circuit breaker.
* Usually an electrical permit and services of a
licensed electrician are required.
* If the supply cord is damaged, it must be
replaced by a special cord or assembly available
from the manufacturer or its service agent.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
The wire which is coloured Green-and-Yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the symbol
or coloured Green or Green-and-Yellow. The
wire which is coloured Blue must be connected
to the terminal which is marked with the letter N
or coloured Black. The wire which is coloured
Brown must be connected to the terminal which
is marked with the letter L or coloured Red.
* Should the socket outlets in the installation site
not be suitable for the plug supplied with your
product, the plug must be removed (cut off if it is
moulded on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used
without a fuse cover being fitted.
5
ENGLISH