Operating Instructions
Instructions for use halogen floodlight with motion sensor Model: H 150P and H 500P
WARNING: Ensure electricity is switched off at mains before installation, replacement of bulb or servicing. Please read through all following instructions
before attempting to install the unit.
The Brennenstuhl halogen lamps must be connected by an approved specialist in accordance with VDE 0100 using a three-core conductor.
The earth wire (greenyellow) must absolutely be connected to the medium terminal. Please refer to
Important: This product has been designed and manufactured to automatically control floodlight at outdoor area once the integral infrared detector has
sensed a human presence. This is not intended for any other application or use.
1. Installation and standard wiring
instructions
1. Do not mount spotlights without stands on a
damp or conducting surface.
2. Not mounting at the vibrational surface.
3. Mounting position: The floodlight should, ideally,
be fixed with the wall fixing bracket as per
Fig. 1. Minimum distance from illuminated area
1 metre.
4. Mark the hole positions for fixing bracket onto
the wall. Drill and plug the wall at the marked
positions. Screw the fixing bracket to the wall
with suitable screw (not supplied). See Fig. 2.
5. Unscrew the junction box cover and remove
diffuser and rubber seal.
6. Put your 3-core mains cable into the junction
box through the plastic stud and rubber gasket.
7. Connect the 3 wires as per Fig. 3.
8. Replace the junction cover. Take care not to
lose the rubber gasket on the cover.
9. Undo Screw/s on the front glass cover and
hinge open. Insert bulb into spring loaded
holders. Do not touch the bulb with bare hand.
Close glass cover and tighten. Ensure that all
seals and grommets are secure see Fig. 4.
10. Mount the unit to the wall fixing bracket with
replacing the two bolts. Adjust the floodlight to
desired position and tighten the two bolts
(refering to the mounting instructions, Fig. 7).
Note: In order to increase the service life of the
halogen lamp, only use/mount the spotlight
horizontally (+/– 15°).
2. Operating instructions of movement
detector
1. You can see the detection area of movement
detector(PIR) as per Fig. 5. You can select
the scanning field of PIR by adjusting the
rotating adjuster and moving the PIR sensor
as show in Fig. 6.
2. You can select the relay time and Lux level
(from daylight to night) by adjusting TIME
and LUX knobs see Fig. 6.
3. The (✹) position indicates that the PIR can
works during daylight and night, the
position indicates that the PIR only work at
night, and you can select the desired Lux
control level by yourself.
4. Must loose the cope stud before rotating
PIR Sensor.
5. Adjusting the detection area by rotating the
PIR Sensor and floodlight.
6. Adjusting the duration time: Turning the TIME
KNOB from – to + will increase the duration
time (refering to the Fig. 6).
7. Adjusting the Lux control level: Turning the
LUX KNOB clockwise to set a time between
day (✹) and night
to switch on the light.
8. Adjusting the sensitivity: Turning the SENS
KNOB from – to + will increase the sensitivity
(refering to the Fig. 6).
9. Walk-Test: Determining the detection area by
Walk-Test. Once the PIR sensor receives a
valid trigger signal (such as movement of a
human body) within its detection area,
the floodlight will be turned on for the preset
period of time. Please placing the LUX
control to »Day« position and the TIME
control to minimum (-) during Walk-Test.
mark in the connection box.
3. Changing the tube
Disconnect the spotlight (switch off). In the
case of the Brennenstuhl halogen spotlight with
steel tube frame, unplug at the mains! Please
release cover of connecting box to enable aeration
of the lamp housing. Do not touch the halogen
tube with bare hands. Use gloves or a cloth.
After replacing the lamp bulb, take care to fit the
seal in the correct position between the lens and
the housing. Please absolutely note the
manufacturer's instructions!
4. Note!
Important: Never attempt to remove the lens
cover, as this will damage the PIR and render all
gurantee invalid.
WARNING: THE FLOODLIGHT MUST BE
EARTHED.
Before touching the halogen spotlight (e.g. when
changing a lamp) please make sure that it is
turned off and has cooled down. Touching a hot
halogen spotlight can cause burns.
A damaged glass lens has to be replaced by an
original one of Brennenstuhl before further
operation of the halogen
spotlight.
Please note the warning mark (label) on the
floodlight.
WARNING: THIS LAMP MAY NOT BE USED
UNLESS ALL SEALING RINGS HAVE BEEN
PROPERLY INSTALLED.
5. Technical Date
Output, voltage and protection class:
see type plate.
Halogen lamp: see type plate, contact distance
H 150P ca. 78 mm, H 500P ca. 118 mm.
Motion Detector:
Detection area: Up to 12 m
Detection angle: 180°
Switch-on period: From 15 (±5) seconds to 5 (±1)
minutes
6. Mounting instructions
See on the last page.