Installation Instructions

GROUND FAULT CIRCUIT INTERRUPTER

Ground Fault Circuit Interrupter (GFCI/GFI) protection is a system that shuts down the
electric circuit (opens it) when it senses an unexpected loss of power, presumably to
ground. GFCI/GFI circuit protection is not recommended with our equipment. If code
requires the use of a GFCI/GFI, then you must follow the local code. The circuit must be
dedicated and sized properly, and there must be a panel GFCI/GFI breaker. We do not
recommend GFCI/GFI outlets as they are known for more intermittent nuisance trips than
panel breakers.

MINIMUM POWER CORD SPECIFICATIONS

Maximum Breaker Size
15 amp
20 amp
If a power cord is used, the wire size to the receptacle is dependent upon location,
materials used, length of run, etc., so it must be determined by a qualified electrician.
Local, state or national requirements will supersede our minimum requirements.
Maximum Breaker Size & Minimum Circuit Amperage Chart

Important
Due to continuous improvements, this information is for reference only. Please refer
to the ice machine serial number tag to verify electrical data. Serial tag information
overrides information listed on this page.
Ice Machine
PKU0155
PKM0335
PKM0425
PKM0535
16
Maximum Fuse
Voltage/Phase/
Cycle
115/1/60
115/1/60
115/1/60
115/1/60
Minimum Wire
Size
14 gauge
12 gauge
Minimum Circuit
or
Circuit Breaker
15
15
20
20
Part Number: 000016426 Rev 00 08/2020
Maximum Length of Power
Cord
6 feet (1.83 m)
6 feet (1.83 m)
Total Amps
Amps
N/A
9.44
11.3
12.7
Section 1
7.4
N/A
N/A
N/A