Installation Instructions

Installation Check List

Is the toggle switch set to ice? (The toggle switch is located behind the front panel).
Is the Ice Machine level?
PKU0155 only - Is the float valve shut-off in the open position?
Have all of the electrical and water connections been made?
Has the supply voltage been tested and checked against the rating on the nameplate?
Is there proper clearance around the ice machine for air circulation?
Is the ice machine grounded and polarity correct?
Has the ice machine been installed where ambient temperatures will remain in the
range of 40° - 110°F (4° - 43°C)?
Has the ice machine been installed where the incoming water temperature will remain
in the range of 40° - 90°F (4° - 32°C)?
Is there a separate drain for the potable water and bin?
Are the ice machine and bin drains vented?
Are all refrigerant lines free from contact with other components?
Are all electrical leads free from contact with refrigeration lines and moving
equipment?
Has the owner/operator been instructed regarding maintenance and the use of
Descaler and Sanitizer?
Has the ice machine and bin been sanitized?
Is the ice thickness set correctly? (Refer to Operational Checks to check/set the correct
ice bridge thickness).