Three options are available if your hood
system has too much restriction:
1. Accept airflow as is.
a. Press the calibration button to
accept airflow as is. The IQ Blower
System™ is now configured to the
highest possible performance. The
blinking calibration light goes out.
Note: The LED will also turn off if
you select any blower speed on
the control.
2. Correct duct restriction, clear the
original calibration data, and repeat
the calibration process.
a. Correct the duct restriction.
SERVICE PARTS
I
Model CC34
KEY NO.
DESCRIPTION
CAS
BLOWER ASSEMBLY
506
BLDC DRIVER
67
WIRES
202
WIRE CLAMP
415
BUSHING
IME
ELECTRICAL INSTALLATION ASSEMBLY
67A
WIRES
115
FEEDER CABLE CONNECTION BOX
415
BUSHING
116
FEEDER CABLE CONNECTION BOX COVER
125
UPPER TELESCOPIC SKELETON
124
BOTTOM TELESCOPIC SKELETON
64
BOTTOM BRACKET
507
CALIBRATION BUTTON ASSEMBLY
439
GROMMET
474
LED LIGHT
250
RING NUT
AQI
SWITCH BOX ASSEMBLY
343
CLOSURE PANEL
477
HINGE
362
DOOR MAGNETS WITH SCREWS
9
GREASE FILTER
ARU
CONNECTION AIR OUTLET SET
ACR3
REMOTE CONTROL
HARDWARE
INSTALLATION INSTRUCTIONS
QSB
b. Clear the original calibration data
by holding calibration button for
10 seconds. The light will blink 3
times to confirm and the blower
configuration will go back to default
settings.
c. Repeat calibration process from
the beginning.
3. Clear calibration data to reset hood
to default factory setting and achieve
standard high pressure blower
performance.
a. Clear calibration data and reset
hood to factory default setting
by holding calibration button for
10 seconds. The light will blink 3
times to confirm and the blower
configuration will go back to default
settings.
- 14 -
PART NO.
B06002259
97019431
B06102601
B03292290
B03202288
B06145222
B06102598
BE3350233
B03292596
BE3351530
B08092797
BE3404965
BE03115251
B06102584
B02320034
B02300431
B02011389
B06102585
B08093078
B02011376
B080811027
B08087804
B08092501
B08999186
B080810994
B080813623