FAAC 624 BLD Manual De Instrucciones página 27

Ocultar thumbs Ver también para 624 BLD:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
if you press F again (and hold it down), the display shows
the name of the next function, etc.
• when you reach the last function, press the push-button
F to exit programming, and the display resumes showing
the inputs status.
1ST LEVEL PROGRAMMING
Display
Function
LOADING PARAMETERS:
dF
00
Neutral condition
0 1
Default FAAC  loaded
02
Default RESERVED FOR FAAC
03
Default FAAC CITY loaded
04
Default FAAC CITY K loaded
05
Default J75 loaded
06
Default J75K loaded
00
LEAVE AT
IF YOU DO NOT WISH TO MAKE ANY
CHANGE TO THE PROGRAMMING.
For an explanation of the dF parameter
refer to page.8.chapter.5.2.
BUS ACCESSORY MENU
bu
For an explanation of this parameter refer to
page.8.chapter.5.3.
FUNCTION LOGICS:
LO
A
Automatic
A 1
Automatic 
E
Semiautomatic
P
Parking
PA
Parking automatic
Cn
Condo
CA
Condo automatic
rb
Faac-City ( traffic bollard logic
C
Dead-man
r
Remote
Cu
Custom
PAUSE TIME:
PA
This operates only if an automatic
logic was selected. Can be adjusted
0
59
from
to
sec. in  second steps.
Subsequently, the display changes to
show minutes and tenths of a second
(separated by a dot) and time is adjusted
in 0 second steps, up to the maximum
4 . 1
value of
minutes.
e.g. if the display shows
time will be  min and 50 sec
POWER:
FO
Adjusts motor power.
0 1
= minimum power
50
= maximum power
LOOP 1:
L 1
If this function is enabled, the loop
connected to the Loop input will have
the OPEN function.
Y
= loop active
n o
= loop not active
Attention: if the function is not enabled,
loop status will nevertheless be available
on one of the outputs, if appropriately set
(see second level programming).
Default
00
E
)
20
2.5
the pause
,
.
50
no
7
Display Function
L 2
LOOP 2:
If this function is enabled, the loop
connected to Loop input will have the
SAFETY/CLOSE function, i.e. it will operate
as SAFETY during the closing stage, and
will command CLOSE to the board at
release.
Y
= loop active
n o
= loop not active
Attention: if the function is not enabled,
loop status will nevertheless be available
on one of the outputs, if appropriately
set.
H 1
BOOST LOOP 1 FUNCTION
Y
n o
= Active
Thanks to this function you can increase
the sensitivity level at the moment of
detection. When the vehicle leaves the
loop, the sensitivity returns to the selected
level. This system holds the detection
contact even in the event of very high
vehicles as well as during the passage of
a tractor with trailer.
H 2
BOOST LOOP 2 FUNCTION
Y
n o
= Active
See BOOST LOOP function.
S 1
SENSITIVITY LOOP 1
Regulates the sensitivity of the loop:
0 1
= minimum
1 0
= maximum
S2
SENSITIVITY LOOP 2
Regulates the sensitivity of the loop:
0 1
= minimum
1 0
= maximum
AUTOMATED SYSTEM STATUS:
St
Exit programming,
memory storage of data set and return to
automated system status view.
00
Closed
0 1
Opening pre-flashing
02
Opening
03
Open
04
In pause
05
Closing pre-flashing
06
Closing
07
Stopped ready to close
08
Stopped ready to open
09
Emergency opening
10
Closing safety device in operation
The display of the automated system status
fundamental importance for the operator assigned
to installation/maintenance, to distinguish the logical
processes the board performs during movements.
If, for example, the automated system is in CLOSED
00
state
must be shown on the display. On reaching
the command OPEN, the display will change to
0 1
, if pre-flashing is enabled, or directly to
(the OPENING movement), to then display
reaching the OPEN position.
Default
no
no
= Not active
no
= Not active
05
05
St
is of
02
03
on

Publicidad

Tabla de contenido
loading

Tabla de contenido