.4.. ELECTRICAL.CONNECTIONS

BEAM
BREAKER
4.1..

J1.TERMINAL-BOARD.-.ACCESSORIES.(FIG..2)

LOOP 1 - Magnetic loop LOOP 1 (OPEN - terminals 1-2): it activates the OPENING function
LOOP 2 - Magnetic loop LOOP 2 (SAFETY/CLOSE - terminals 3-4): it activates the SAFETY/CLOSING function
OPEN - "Opening" Command (N.O. - terminal 5): this refers to any pulse generator ( e.g.: push-button) which, by closing
a contact, commands the barrier to close and/or open.
CLOSE - "Closing" Command (N.O. - terminal 6): this refers to any pulse generator (e.g.: push-button) which, by closing
a contact, commands the barrier to close.
FSW - Closing safety-devices contact (N.C. - terminal 7). The purpose of the closing safety devices is to protect the
barrier movement area during closure, by reversing motion. They are never tripped during the opening cycle. If the closing
Safety devices are engaged when the automated system is in open status, they prevent the closing movement.
If.closing.safety.devices.are.not.connected,.jumper.connect.the.FSW.and.GND.terminals.(fig..6).
STOP - STOP contact (N.C. - terminal 8): this refers to any device (e.g.: push-button) which, by opening a contact, can
stop the motion of the automated system.
If.stop.safety.devices.are.not.connected,.jumper.connect.the.STOP.and.GND.terminals.(fig..6).
EMERGENCY - EMERGENCY contact (N.C- terminal 9): this refers to any switch which, by being activated in emergency
state, opens the barrier and stops its movement until the contact is restored.
If.emergency.safety.devices.are.not.connected,.jumper.connect.the.EMERGENCY.and.GND.terminals.(fig..6).
GND ( terminals 10-11-19) - Negative contact for feeding accessories
24 Vdc ( terminals 12-13)- Positive contact for feeding accessories
.
Max..load.of.accessories:.500.mA..To.calculate.absorption.values,.refer.to.the.instructions.for.individual.
accessories
OUT 1 - Output 1 GND open-collector (terminal 14): The output can be set in one of the functions described in the
nd programming level (see par. 5..). Default value is FAILSAFE. Maximum load: 24 Vdc with 100 mA.
OUT 2 - Output 2 GND open-collector (terminal 15): The output can be set in one of the functions described in the
nd programming level(see par. 5..). Default value is CLOSED beam. Maximum load: 24 Vdc with 100 mA.
OUT 3 - RELAY Output 3 (terminal 16-17): The output can be set in one of the functions described in the nd programming
level (see par. 5..). Default value is INDICATOR LIGHT: Maximum load: 24 Vdc or Vac with 500 mA.
.
To.avoid.endangering.correct.operation.of.the.system,.do.not.exceed.the.indicated.power.indicated.in.fig..2.
OUT 4 - Output 4 open-collector +24Vdc (terminal 18): The output can be set in one of the functions described in the
nd programming level (see par. 5..). The default value for ALL THE PRE-SETTINGS is BUS COMMUNICATION. Maximum
load: 24 Vdc with 100 mA.
To connect the
230 V
photocells and
or 115 V~
safety devices,
60W max
consult paragraph
4.2.
* 0 V~ board version
or 5 V~ board version
4
MOTOR THRUST
CAPACITOR
MOTOR
FAN
~
*
230 V
or 115 V~
50/60 Hz
~
*
Fig. 2