Electrical Connections; Encoder Connection - Erreka AXIL Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ELECTRICAL CONNECTIONS

Models 230V and 120V
Earth-fault protection
Opening
Common
Closing
m
ATTENTION:
• Always connect the ground cable as stipulated by
enforced norms (EN 60335-1, EN 60204-1).
• For the connection only use cables 4G0,75 or 4G1 with
ø external 10 mm maximum
Finish the electrical connections closing the rear space of the
motor with the plastic cover and locking the cable press.
Models 24V
Earth-fault protection
+
-
not used
m
ATTENTION:
• Always connect the ground cable as stipulated by
enforced norms (EN 60335-1, EN 60204-1).
• For the connection only use shielded cable AYCY4.
Finish the electrical connections closing the rear space of the
motor with the plastic cover and locking the cable press.

ENCODER connection

m
ATTENTION:For encoder operation, when in the closed
position, both gate panels must rest against a mechanical stop.
Hereafter the directions to follow to connect the cables of the
encoder to the control unit:
ENCODER
CONTROL UNIT
M
RED
V+ (brown)
O
T
BLACK
GND (shield)
O
R
BLUE
SNG1 (green)
1
M
RED
V+ (brown)
O
T
BLACK
GND (shield)
O
R
BLUE
SNG1 (green)
2
m
ATTENTION: extensions of the cables must be made only
with a 4x0,22 shielded cable with polyethylene sheath
m
ATTENTION: check that the ground of the power supply of
the accessories is connected to the common accessories.
Finish the electrical connections closing the rear space of the
motor with the plastic cover and locking the cable press.
24

Publicidad

Tabla de contenido
loading

Tabla de contenido