Stihl MSA 200 C Manual De Instrucciones página 92

Ocultar thumbs Ver también para MSA 200 C:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 151
English
Troubleshooting
Always remove the battery from the machine before starting any work on the machine.
Fault
Machine does not start when switched on
Machine switches off in operation
90
Cause
No electrical contact between machine
and battery
Battery discharged
(1 LED on battery flashes green)
Battery too hot / too cold
(1 LED on battery is red)
Battery fault
(4 LEDs on battery flash red)
Unit too hot
(3 LEDs on battery are red)
Electromagnetic malfunction or fault in
machine
(3 LEDs on battery flash red)
Moisture in the machine and/or battery
Battery or machine electronics too hot
Electrical or electromagnetic malfunction Remove battery and reinsert it
Remedy
Remove battery, visually inspect the
contacts and reinsert the battery
Charging a battery
Let the battery cool off / let the battery
warm up gradually at temperatures of
approx. 15 °C - 20 °C
Remove battery from the machine and
reinsert it. Turn on the machine – if the
LEDs still flash, the battery is faulty and
must be replaced
Let the machine cool off
Remove battery from the machine and
reinsert it. Turn on machine – if the LEDs
still flash, the machine is faulty and must
be checked by a servicing dealer
Let the machine/battery dry
Remove battery from the machine, let
battery and machine cool off
1)
MSA 200 C

Publicidad

Tabla de contenido
loading

Tabla de contenido