Receiver Programming (Only For T11) - Aprimatic T11 Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

AUTOMATIC MODE. If you select this operating mode, when a pulse is given, opening
is commanded until the work time expires, the gate remains open for the selected
pause time and it then closes automatically.
• If a pulse is sent during opening, the control system ignores it and the gate
continues to open.
• If a pulse is sent or the photocells are obscured during closing, the direction is
inverted (the gate re-opens).
• During the pause stage and when the photocells are obscured, the device will
remain in pause until the photocells are cleared.
SEMIAUTOMATIC MODE WITH STOP. If you select this operating mode when the
gate is closed, when a start pulse is given, the gates open until the set work time
expires. If another start pulse is given during opening, the gates stop immediately
until another start pulse is given: this closes the automation. A start pulse sent during
closing re-opens the gates.
SUPER AUTOMATIC MODE. When you select this type of operating and a start pulse
is given, the gate opens as far as the limit switch and stays open for the pre-set pause time
and then closes automatically.
A start pulse given during any stage reverses the direction: you can close the gate with
a command.
• A pulse given during the pause triggers pre-fl ashing and subsequent closing of the gate.
DIP-SWITCHES 4 and 5 (GATE CLOSING DELAY) - These SWITCHES are used to
adjust the gate closing delay for motor 1 (delayed closing), compared to the start up of
motor 2 (immediate). It can be set at 0, 3, 9 or 16 seconds.
DIP-SWITCH 6 (PRE-FLASHING) - This SWITCH is used to enable or disable pre-
fl ashing. It is possible for both the opening and closing stages. If the function is enabled,
before the automation opens or closes, there will be a signal for 3 seconds and the
warning light and fl ashing lights will come ON before the gates move.
DIP SWITCH 7 (PAUSE PHOTOCELL) - This SWITCH is used to select the pause
photocell function when the automatic functioning mode is enabled. When the SWITCH
is in the ON position, if the photocell beam is interrupted and cleared with the automation
in pause, the device will command pre-fl ashing for 3 seconds and will then close the
gate, even if the pause time has not been concluded. When the SWITCH is in the OFF
position, the gate will only close when the set pause time expires.
ENGLISH
DIP SWITCH 8 (PEDESTRIAN START OR OPENING SAFETY DEVICE) - This
SWITCH is used to select the type of input for terrminal 6. When the SWITCH is in the
ON position, the input functions as an opening safety device. When the SWITCH is in
the OFF position, the input is enabled for single wing functioning (motor 1).
NOTE - This selection (ON/OFF) is valid for all operating modes, except Dead Man
mode. In this case, the input is always used as the closing input function.
DIP SWITCH 9 - LEAVE IN THE FACTORY-SET POSITION (OFF).
DIP SWITCH 10 (ENABLE/DISABLE ANTI-CRUSH CONTROL) - If the device
controls APRIMATIC electromechanical operator, set the dip-switch to the ON position
(anti-crush card enabled).
If the device controls APRIMATIC hydraulic operators, set the dip-switch to the
OFF position.
3.4 RECEIVER PROGRAMMING
JP5-8 (ENABLING BUTTON) - Using the jumpers JP5-8, you can select which receiver
output channel and, therefore, which remote control button, will enable the output
signal. This selection is made by closing just one of the jumpers present, following
the scheme indicated below:
Ch4
JP5 – Channel 1 - Button 1
JP8
JP6 – Channel 2 - Button 2
Ch3
JP7 – Channel 3 - Button 3
JP7
OUT RX
JP8 – Channel 4 - Button 4.
Ch2
JP6
WARNING: Only close one jumper or you
Ch1
risk breaking the unit !
JP5
JP3-4 (ENABLING BUTTON ROW) - The receivers may be used with 2-4 or 14-button
remote controls. If you use it with a 14-button remote control, you can use the jumpers
JP3 and JP4 to defi ne which row of buttons the receiver must respond to, following
the scheme indicated below:
JP3 – JP4 open: row 1 (Buttons 1-4)
JP3 closed: row 2 (Buttons 5-8)
JP4 closed: row 3 (Buttons 9-12)
JP3 – JP4 closed: row 4 (Buttons 13-14).
7

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T1e

Tabla de contenido