TROUBLES-REMEDIES
Sudden Starts. If power is on to pump when
thermal overload resets, pump may start without warn-
ing. If you are working on pump, you may get an
A. Pump fails to operate:
B. Pump fails to empty sump:
C. Pump will not shut off:
Myers
warrants to the original consumer purchaser ("Purchaser" or "You") of the products listed below, that they will be free
®
from defects in material and workmanship for the Warranty Period shown below.
Product
Jet pumps, small centrifugal pumps,
submersible pumps and related accessories
Fibrewound Tanks
Steel Pressure Tanks
Sump/Sewage/Effluent Products
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
Wastewater Solids Handling Pumps
Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog
and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper
installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power
through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient
compensated, extra-quick trip overload relays of the recommended size or the warranty is void. Your only remedy, and MYERS's
only duty, is that MYERS repair or replace defective products (at MYERS's choice). You must pay all labor and shipping charges
associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered.
No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.
MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an
implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You
may also have other rights which vary from state to state. This Limited Warranty is effective April 1, 2014 and replaces all undated
warranties and warranties dated before April 1, 2014.
293 Wright Street, Delavan, WI 53115 • Phone: 888-987-8677 • Fax: 800-426-9446 • www.femyers.com
In Canada: 490 Pinebush Road, Unit 4, Cambridge, Ontario N1T 0A5 • Phone: 800-363-7867 • Fax: 888-606-5484
electrical shock or impeller may catch fingers or tools.
Disconnect power before servicing pump.
1. Check to be sure that power cord is securely plugged into outlet or securely wired
into controller or switch box. Disconnect power to outlet before handling pump
or motor.
2. Check to be sure you have electrical power.
3. Check that liquid fluid level is high enough to activate switch or controller.
4. Check to be sure that 5 mm (3/16'') vent hole in discharge pipe is not plugged.
5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.
6. Thermal overload may have tripped. Test start pump; if it starts and then stops
immediately, disconnect from power source for 30 minutes to allow motor to cool,
then reconnect to power source. Check for cause of overheating/overloading.
1. Be sure all valves in discharge piping are fully open.
2. Clean out discharge pipe and check valve.
3. Check for blockage in pump inlet or impeller.
4. Pump not sized properly. A higher capacity pump may be required.
1. Check switch or controller automatic floats for proper operation and location.
See installation instructions for switch/controller.
2. If pump is completely inoperative or continues to malfunction, consult your
local serviceman.
Limited Warranty
Warranty Period whichever occurs first:
12 months from date of original installation,or 18 months from date of manufacture
5 years from date of original installation
5 years from date of original installation
12 months from date of original installation,or 36 months from date of manufacture
12 months from date of original installation,or 18 months from date of manufacture
24 months from date of original installation,or 30 months from date of manufacture