11 Cut the front of the liner (9) back 40 mm (or 53 mm if using the sealing plug (10)) and grind
it to an angle of 40°. The liner's insulation must not be further removed in either case.
12 Deburr the cutting edges.
13 Screw the insulating piece (2) hand tight into the torch neck seat (small edge first).
14 Push in the liner (9).
The remaining excess length of the nipple (approx. 14 mm) of the liner (9) is used to preload
the liner.
15 Screw on the nut (6).
5.4.2 PA liner
NOTICE
• New, as yet unused PA liners have to be abridged to the actual length of the cable
assembly.
• For PA liners with an outer diameter of 4.00 mm, the capillary tube in the distance
adaptor must be replaced with a guide tube.
For using aluminium, copper, nickel and stainless steels.
 Fig. 3 Mounting the liner for ABIMIG
1 Disconnect the cable assembly (4) on the machine side and lay it out straight.
2 Unscrew the nut (6) from the central connector (7).
3 Sharpen the start of the PA liner to an angle of 40° using an ABICOR BINZEL sharpener.
4 ABIMIG
Slide the sharpened liner into the contact tip up to the stop.
ABIMIG
Slide the sharpened liner into the torch neck liner up to the stop (with the torch neck
mounted).
ABIMIG
Slide the sharpened liner through the wire conduit into the insulating bush (2) of the torch
handle up to the solid stop.
5 Push the retaining nipple, O-ring and nut (6) onto the PA liner.
6 Maintain the pressure on these and tighten the nut (6).
7 Introduce the central connector (7) together with the long PA liner through the central socket
into the wire feeder.
8 Mark the PA liner directly in front of the rolls and disconnect the central connector again (7).
9 Cut off the PA liner with the ABICOR BINZEL cutter where marked.
10Sharpen the start of the PA liner to an angle of 40° using the ABICOR BINZEL sharpener.
BAL.0402.0 • 2018-08-24
®
®
A LW/ABIMIG
W or with undivided wire guide:
®
A T LW:
®
W T:
®
W T torches on page EN-10
5 Putting into operation
EN - 11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abimig a t lwAbimig wAbimig w t

Tabla de contenido