Attaching The Cable Assembly On The Machine Side; Connecting The Coolant - Abicor Binzel ABIMIG A Instructivo De Servicio

Ocultar thumbs Ver también para ABIMIG A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5 Putting into operation

5.5 Attaching the cable assembly on the machine side

 Fig. 3 Mounting the liner for ABIMIG
1 Join the central connector (7) and the central socket at the wire feeder.
2 Use the connection nut (5) to secure both of these.
3 Attach the cooling water supply and return connectors to the ABIMIG
4 Attach the shielding gas and control lead connectors in the case of other machine
connections.

5.6 Connecting the coolant

WARNING
Risk of burns
The cable assembly overheats if the coolant level is too low.
• Wear the correct protective gloves.
• Check the coolant level at regular intervals.
1
4
1
Control lead
2
Coolant supply hose
Fig. 6
Connecting the coolant
EN - 14
®
W T torches on page EN-10
2
3
Coolant recirculator
ABIMIG
®
W / W T.
3
4
Coolant return hose
BAL.0402.0 • 2018-08-24
®