5 Putting into operation
5.5 Attaching the cable assembly on the machine side
Fig. 3 Mounting the liner for ABIMIG
1 Join the central connector (7) and the central socket at the wire feeder.
2 Use the connection nut (5) to secure both of these.
3 Attach the cooling water supply and return connectors to the ABIMIG
4 Attach the shielding gas and control lead connectors in the case of other machine
connections.
5.6 Connecting the coolant
WARNING
Risk of burns
The cable assembly overheats if the coolant level is too low.
• Wear the correct protective gloves.
• Check the coolant level at regular intervals.
1
4
1
Control lead
2
Coolant supply hose
Fig. 6
Connecting the coolant
EN - 14
®
W T torches on page EN-10
2
3
Coolant recirculator
ABIMIG
®
W / W T.
3
4
Coolant return hose
BAL.0402.0 • 2018-08-24
®