5.1 2-cycle function of the trigger

6 Putting out of operation

7 Maintenance and cleaning

7.1 Cable assembly

Using a standard welding torch, the two-cycle mode of the trigger can be
activated. Further operating modes and handle modules depend on the
corresponding welding power supply and must be ordered separately.
1 Press the trigger on the handle and keep it pressed = welding is started.
2 Release the trigger = welding is stopped.
NOTE
• Liquid-cooled cable assemblies start leaking when overheated. This is
why the cooling unit should continue running for approx. 5 min. after
welding.
1 Wait until the shielding gas flow has subsided and then switch off the power
supply.
2 Close the valve of the shielding gas cylinder.
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, installation, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply and cut off the gas supply.
• Close off the compressed-air supply and pull the main plug.
1 Unscrew the cable assembly on the machine side and bring it into a
stretched position.
2 Unscrew nut and pull out liner or PA liner and replace it, if necessary.
3 Remove wear parts from the torch neck.