0x004B
Output filter
0x004C
Modo Eco
0x004D
PIN code
Disable continuous
0x004E
sucking
D
ATOS DE PARÁMETROS
Índice
Parámetro
SPDU
0x0064
Setpoint H1
0x0065
Hysteresis h1
0x0066
Setpoint H2
0x0067
Hysteresis h2
0x0068
Setpoint HP1
0x0069
Hysteresis hP1
0x006A
Duration auto blow
Permissible
0x006B
evacuation time
Permissible leakage
0x006C
value
D
ATOS DE PARÁMETROS
Índice
Parámetro
SPDU
Vacuum sensor
0x0078
offset Calibration
Pressure sensor
0x0079
offset Calibration
Reset erasable
0x007A
counters
0x007B
Factory defaults
D
ATOS DE PARÁMETROS
Índice
Parámetro
SPDU
0x0082
Error-Code
S
C H MA L Z
1 byte
0 - 3
1 byte
0 - 1
2 byte
0 - 999
1 byte
0 - 1
– P
S
RODUCTION
ETUP
Longitud Rango
2 byte
H1 =< 998 & H1 > (H2+h1)
2 byte
h1 < (H1-H2) & h1 >= 10
2 byte
H2 < (H1-h1) & H2 > h2+2
2 byte
h2 < H2-2 & h2 >= 10
2 byte
HP1 < 9.900 & HP1 > hP1
2 byte
hP1 < HP1 & hP1 > 100
2 byte
10 - 999
2 byte
0 - 999
1 byte
0 - 6
– C
ALIBRATION
Longitud Rango
1 byte
0 - 1
1 byte
0 - 1
1 byte
0 - 1
1 byte
0 - 1
– E
RROR
Longitud Rango
1 byte
0 - 255
SXP
/ SXMP
I
I
0 = Off
1 = 10ms
rw
2 = 50ms
3 =200ms
0 = Eco OFF
rw
1 = Eco ON
0 = unlocked
rw
>0 = locked
0 = NO
rw
1 = YES
r/w
Nota
0 = Nothing
wo
1 = Zero offset; After calibrating 0
0 = Nothing
wo
1 = Zero offset; After calibrating 0
0 = Nothing
wo
1 = Reset erasable counters
0 = Nothing
wo
1 = Restore; After restoring 0
r/w
Nota
ro
5-57
r/w
Nota
rw
Unit: mbar
rw
Unit: mbar
rw
Unit: mbar
rw
Unit: mbar
rw
Unit: 1 bar x 0,1
rw
Unit: 1 bar x 0,1
rw
Unit: 1 ms x 10
rw
Unit: 1 ms x 10
0 = 4mbar/s
1 = 11mbar/s
2 = 25mbar/s
rw
3 = 50mbar/s
4 = 100mbar/s
5 = 150mbar/s
6 = 250mbar/s