Controlling combustion air

The appliance has various features for air control; see
following figure.
The primary air slide is open in pulled out
1.
position and closed in pushed back position.
The secondary air slide is open in pulled out
2.
position and closed in pushed back position.
The primary air slide controls the air flow under the
grille (1);see following figure.
The secondary air slide controls the air flow for the
glass and the vents in the back wall (2).
14
Advice
Never burn wood with an open door.
Regularly burn wood with intense roaring fires.
If you frequently have low intensity fires, tar
and creosote may be deposited in the chimney
. Tar and creosote are highly combustible
substances. Thicker layers of these