LOGIC MENU (LoGIc)
Press "OK" to display one of the following submenus:
Display
By default
Automatic closure
OFF
(tcA)
3 steps
OFF
(3 StEP)
Pushbutton inhibit
OFF
(IbL oPEn)
Fast closure
OFF
(FASt cLS)
Photoelectric cells
OFF
during opening
(Photoc. oPEn)
Photoelectric cell tests
OFF
(tESt Phot)
Copyright © 2008 Somfy SAS. All rights reserved.
Description
Automatic closure mode operation.
The gate will close automatically once the programmed time delay (tcA) times out.
ON: after a time delay, triggers automatic closure
OFF: switches off automatic closure
"3 step": semi-automatic mode operation (refer to the User's Manual).
"4 step": sequential mode operation (refer to the User's Manual).
ON: Switches on 3 step logic. Pressing START once has the following effect:
•
gate closed: the gate opens
•
gate moving (opening): the gate stops and the automatic closure time is switched on (only if
the latter function is set to ON)
•
gate open: the gate closes
•
gate moving (closing): the gate stops and opens again
OFF: Switches on 4 step logic. Pressing START once has the following effect:
•
gate closed: the gate opens
•
gate moving (opening): the gate stops and the automatic closure time is switched on
(only if the latter function is set to ON)
•
gate open: the gate closes
•
gate moving (closing): the gate stops and the automatic closure time is not switched on
•
once the gate stops moving: the gate opens
Blocks out pushbutton functions while the gate is opening.
ON: while opening only
OFF: no inhibit function
The gate closes three seconds after clearing the photoelectric cells and before reaching the
end of the confi gured automatic closure time.
ON: command enabled
OFF: command disabled
ON:
•
in closing mode, the gate stops then reverses its movement.
•
in opening mode, cells are inactive.
OFF:
•
in closing mode, the gate stops and reverses its movement once the cells are no longer
obstructed.
•
in opening mode, the gate stops then continues its movement once the cells are no longer
obstructed.
Activates the photoelectric cell test.
ON: command enabled
OFF: command disabled
11