Symbols In The Document; Intended Use - SMA MD SEN-US-40 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SMA Solar Technology AG
1.5

Symbols in the Document

Symbol
Explanation
Information that is important for a specific topic or goal, but is not safety-rele-
vant
Section in which the installation and commissioning process is illustrated
graphically.
2
Safety
2.1

Intended Use

The SMA Sensor Module is a module for SMA inverters. The SMA Sensor Module has different
interfaces for connecting various sensors. The SMA Sensor Module converts the signals of the
connected sensors and transmits them to the inverter.
The SMA Sensor Module has the following interfaces:
• Two temperature inputs for connecting the temperature sensors
• One analog input for voltage or current signals (e.g. of an irradiation sensor)
• One supply voltage for a signal source (e.g. of an irradiation sensor)
• One S0 interface (e.g. for connecting an anemometer or energy meter)
The product must only be installed in the following SMA inverters:
• STP 50-US-40 (Sunny Tripower CORE1-US)
• STP 33-US-41 (Sunny Tripower CORE1-US)
• STP 50-US-41 (Sunny Tripower CORE1-US)
• STP 62-US-41 (Sunny Tripower CORE1-US)
• SB3.0-1SP-US-40 (Sunny Boy 3.0-US)
• SB3.8-1SP-US-40 (Sunny Boy 3.8-US)
• SB5.0-1SP-US-40 (Sunny Boy 5.0-US)
• SB6.0-1SP-US-40 (Sunny Boy 6.0-US)
• SB7.0-1SP-US-40 (Sunny Boy 7.0-US)
• SB7.7-1SP-US-40 (Sunny Boy 7.7-US)
• SB3.0-1TP-US-40 (Sunny Boy 3.0-US)
• SB3.8-1TP-US-40 (Sunny Boy 3.8-US)
• SB5.0-1TP-US-40 (Sunny Boy 5.0-US)
• SB6.0-1TP-US-40 (Sunny Boy 6.0-US)
• SB7.0-1TP-US-40 (Sunny Boy 7.0-US)
• SB7.7-1TP-US-40 (Sunny Boy 7.7-US)
The inverter still complies with the standard after the product has been installed.
The product must only be operated with temperature sensors with a Pt100 measuring shunt or a
Pt1000 measuring shunt.
Quick Reference Guide
MDSEN-US-40-IS-xx-13
2 Safety
5