Abicor Binzel ABIMIG XX0 Instructivo De Servicio página 27

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

®
ABIMIG
XX0/XX5
5.2.1 Liner
®
ABIMIG
XX0/XX5 product range and ABIMIG
®
ABIMIG
XX0 T/XX5 T product range and ABIMIG
NOTICE
• New and unused liners must be abridged to the actual length of the
cable assembly.
For use of steel wires with undivided wire guide.
1 Lay down the BIKOX
contact tip from the torch neck.
2 Unscrew nut from the central connector or direct connector and slide liner
®
through the BIKOX
3 Screw down nut again, tighten using the ABIMIG wrench and cut off excess
length of the liner flush with the tip adaptor.
4 Screw in contact tip and gas nozzle.
For use of steel wires with divided wire guide.
1 Lay down the BIKOX
repluggable torch neck.
2 Unscrew nut from the central connector and slide liner through the BIKOX
cable assembly up to the retaining nipple.
3 Screw down nut again, tighten using the ABIMIG wrench and cut off excess
length at the handle threaded part so that it protrudes 2 mm.
4 Screw down rotating or repluggable torch neck again at the handle.
®
A XX5 GRIP product range
®
cable assembly straight and unscrew gas nozzle and
cable assembly up to the retaining nipple.
®
A T XX5 LW product range
®
cable assembly straight and unscrew rotating or
5 Putting into operation
EN - 11
®

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abimig xx5Abimig xx0tXx5tAbimig a xx5 gripAbimig a t xx5 lw

Tabla de contenido