3. Do not operate the pump in a dry basin. This will cause the pump to
become extremely hot, causing burns if touched and/or damage to
the pump.
4. Do not oil the motor. The pump housing is sealed. A high-grade
dielectric oil devoid of water has been put into the motor housing
at the factory. Use of other oil could cause serious electric shock
and/or permanent damage to the pump.
5. Do not install in locations classified as hazardous in accordance with
the National Electrical Code, ANSI/NFPA 70.
6. In any installation where property damage and/or personal injury
might result from inoperative or leaking pump due to power outages,
discharge line blockage, or any other reason, a backup system(s)
and/or alarm should be used.
INSTALLATION
For automatic operation, plug or wire pump into a low-level shut-off
switch. Installation instructions are included with all Little Giant switches
and controllers and should be referred to for installation.
The pump will run continuously when plugged directly into an electrical
outlet. Care should be taken to prevent pump from running dry.
Pump must be placed on a hard level surface. Never place pump directly
on clay, earth or gravel surfaces.
For easier installation and removal, use a Little Giant 3" discharge kit (if
necessary).
The remainder of the discharge line should be as short as possible with
a minimum of turns to minimize friction head loss. Do not restrict the
discharge to sizes below 3".
Check local electrical and building codes before installation. The
installation must be in accordance with their regulations as well as the
most recent National Electrical Code (NEC).
To conform to the National Electrical Code, all pumps must be wired with
14 AWG or larger wire. For runs to 250 feet, 14 AWG wire is sufficient. For
longer runs, consult a qualified electrician or the factory.
Pump should be connected or wired to its own circuit with no other
outlets or equipment in the circuit line. Fuses and circuit breaker should
be of ample capacity in the electrical circuit (see below).
H.P.
VOLTAGE
1/2, 1
1/2, 1
FLOW - LITERS/HOUR
Figure 2
FLOW - GALLONS/HOUR
2
WIRING
FUSE OR CIRCUIT
BREAKER AMPS
115
20
230
15
MAINTENANCE AND SERVICE
If pump does not operate properly, consult the Troubleshooting section.
If trouble cannot be located with these steps shown, consult your pump
dealer or take pump to an authorized service center.
CAUTION: When working on pump or switch, always unplug pump power
cord in addition to removing fuse or shutting of circuit breaker before
working on pump.
CLEANING IMPELLER AND VOLUTE
WARNING: DO NOT REMOVE ANY SCREWS OTHER THAN THOSE
INDICATED BELOW. THE MOTOR SECTION OF YOUR PUMP IS
PERMANENTLY LUBRICATED WITH DIELECTRIC OIL AND SEALED
AT THE FACTORY. REMOVAL OF ANY OTHER SCREWS BY ANYONE
OTHER THAN AN AUTHORIZED LITTLE GIANT SERVICE CENTER
WILL BREAK THIS SEAL AND VOID THE WARRANTY.
1. Remove the 4 bolts (item #18 on parts list) that hold the volute to the
motor housing.
2. Clean impeller and volute passage.
3. Be sure impeller turns freely after cleaning.
INTRODUCTION
FR
Cette feuille d'instructions vous fournit les informations nécessaires pour
entretenir et faire fonctionner votre produit. Conserver ces directives afin
de pouvoir les consulter plus tard.
Le produit que vous avez acheté a été soigneusement fabriqué avec des
matériaux de la plus haute qualité et a été conçu pour durer longtemps
et offrir un service fiable. Les produits sont soigneusement testés,
inspectés et emballés afin d'en assurer la sécurité de fonctionnement
et une livraison en bonne condition. Vérifier attentivement le produit
afin de vous assurer qu'il n'a pas été endommagé pendant le transport.
S'il est endommagé, veuillez contacter l'entreprise qui vous l'a vendu.
Si une réparation ou un remplacement est requis, elle vous prêtera
assistance.
LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER
À L'INSTALLATION, À L'UTILISATION OU À L'ENTRETIEN DU
PRODUIT. SE FAMILIARISER AVEC LES APPLICATIONS, LES
LIMITES ET LES RISQUES POTENTIELS DU PRODUIT. ASSURER
SA PROPRE PROTECTION ET CELLE DES AUTRES EN SUIVANT
TOUTES LES RÈGLES DE SÉCURITÉ. LE NON-RESPECT DE CES
DIRECTIVES PEUT ENTRAÎNER DES BLESSURES ET/OU DES
DOMMAGES MATÉRIELS!
CARACTÉRISTIQUES TECHNIQUES
TAILLE D'ÉCOULEMENT : 14S – 3 po, 16S – 3 po
CAPACITÉ D'EMPLOI : Solides sphériques de 2 po
BOÎTIER : Fonte
VOLUTE : Fonte
TURBINE : Pompe anticolmatage en fonte avec soupapes de sécurité.
MOTEUR : PSC, 1625 tours/min, avec protection automatique contre
les surcharges
ATTACHES : Acier inoxydable, série 300
PALIER : Bille
Figure 3 - Typical Installation
Rubber coupling
Check valve
Male adapter
Elbow